Electriq Power PowerPod 2 Installation Manual page 130

Hide thumbs Also See for PowerPod 2:
Table of Contents

Advertisement

Appendix / Technical Specifications (AC)
Product Model
Dimensions (W / H / D)
(inverter)
Dimensions (W / H / D)
(auto-transformer)
Weight (inverter)
Weight (auto-transformer)
Warranty Inverter
STANDARD COMPLIANCE
Safety
Grid Connection Standards
Emissions
Standards
Standards in progress
Battery Model
Battery
Battery type
Cells
Chemistry
Number of 2.5 kWh
Modules
Nameplate Capacity
Battery Layout
Voltage, Nominal
Continuous Charge Current
Continuous Discharge
Current
Maximum Charge Current
Maximum Discharge Current
Continuous Charge Power
(Nominal)
Continuous Discharge
Power (Nominal)
Maximum Charge Power
(Nominal)
Maximum Discharge
Power (Nominal)
Optimum Operating
Temperature Range
Charge Temperature
Discharge Temperature
Communication Interface
Power Switch, ON / OFF
Cycles
Service Life (40% Capacity
Reduction)
Altitude
Dimensions (W / H / D)
(BMS & battery module)
130
PP2-
PP2-
AC-10/15/20-9600
AC-10/15/20-8600
16.3in x 31.1in x 6.9in (415mm x 791mmx 175mm)
13.6in x 10.9in x 6.9in (345mm x 280mmx 175mm)
102.4 VDC (89.6 – 115.2 VDC)/ 153.6 VDC (134.4 – 172.8 VDC/ 204.8 VDC (179.2 – 230.4 VDC)
5120/7700/9600 W
5120/7700/8600 W
5120/7700/9600 W
5120/7700/8600 W
6150/7700/10,240
6150/7700/10,240
W
W
6150/7700/10,240
6150/7700/10,240
W
W
0° C to 30° C (32°F to 86° F). See detailed temperature guidelines below. Do not install outdoors in climates where the temperature
drops below 0° C (32°F) for extended periods. Do not install in direct sunlight.
17.5" x 7.5" x 8.9" / 445mm x 190mm x 226mm
PP2-
PP2-
AC-10/15/20-7600
AC-10/15/20-7000
70.5lb (32kg)
50lb (22kg)
10 years
UL9540, UL1973, UL1741SA, CSA 22.2
IEEE 1547A, IEEE 1547.1
FCC part15 class B
Rule 21, HECO
Hawaii TrOV2, FVRT
Zhongneng Technology Lithium-ion
Lithium-ion
CATL
LFP - Lithium iron phosphate
4/6/8 in Series
10/15/20 kWh
1 parallel 32/48/64 series
50 ADC
50 ADC
60 ADC
60 ADC
5120/7600/7600 W
5120/7000/7000 W
5120/7600/7600 W
5120/7000/7000 W
6150/7700/9120 W
6150/7700/8400 W
6150/7700/9120 W
6150/7700/8400 W
(0 °C to 55 °C)
(-20 °C to 55 °C)
RJ-45 RS-485
Yes
For Daily Cycle Applications
10 Years
2000 m
PP2-
PP2-
AC-10/15/20-6000
AC-10/15/20-5000
5120/6000/6000 W
5000/5000/5000 W
5120/6000/6000 W
5000/5000/5000 W
6150/7200/7200 W
6000/6000/6000 W
6150/7200/7200 W
6000/6000/6000 W
Installation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PowerPod 2 and is the answer not in the manual?

Table of Contents

Save PDF