Continuity Test - VOLTCRAFT VC292 Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

12.14 Continuity test

Ensure that all objects that you want to measure (including circuit compo-
nents, circuits and component parts) are disconnected and discharged.
1. Switch the DMM on and select
2. Press the SEL/
The continuity test symbol and the Ω symbol will appear on the display.
Æ
3. Press the SEL/
again to switch to the next mode.
4. Insert the red test lead into the
Ω measurement socket and
the black test lead into the
COM"measurement socket.
If the measured resistance
Æ
is equal to or less than 10
Ω, the multimeter will beep
to indicate continuity. There
is no further beeping from
>100 Ω. The continuity test
measures resistances of up
to 600 Ω.
"OL" (overload) indicates
Æ
that the measurement range has been exceeded or that the circuit is broken.
5. After taking a measurement, remove the leads from the measured object and
switch the DMM off.
90
mode.
button once to switch to the mode.
button

Advertisement

Table of Contents
loading

This manual is also suitable for:

2576863