E2S E2xL15R Instruction Manual

Loudspeakers for use in hazardous locations
Hide thumbs Also See for E2xL15R:

Advertisement

Quick Links

INSTRUCTION MANUAL
E2xL15R, E2xL15F, E2xL25R, E2xL25F Loudspeakers
For use in Hazardous Locations
E2XL15R / E2XL25R
1) Product Table
E2xL15FV070 / E2xL15RV070
E2xL25FV070 / E2xL25RV070
E2xL15FV100 / E2xL15RV100
E2xL25FV100 / E2xL25RV100
E2xL15FR008 / E2xL15RR008
E2xL25FR008 / E2xL25RR008
E2xL15FR016 / E2xL15RR016
E2xL25FR016 / E2xL25RR016
Table 1: Electrical Ratings.
2) Warnings
 DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
 DO NOT OPEN WHEN ENERGISED
 POTENTIAL ELECTROSTATIC CHARGING
HAZARD - CLEAN ONLY WITH A DAMP
CLOTH
 HIGH VOLTAGE SHOCK HAZARD. WAIT 5
MINUTES AFTER REMOVING POWER
BEFORE OPENING THE ENCLOSURE
Avertissement:
 NE PAS OUVRIR UN PRESENCE
D'ATMOSPHERE EXPLOSIVE
 NE PAS OUVRIR ENERGIE
 DANGER POTENTIEL CHARGE
ÉLECTROSTATIQUE - NETTOYER
UNIQUEMENT AVEC UN CHIFFON HUMIDE
 HAUT TENSION, RISK DE CHOC.
ATTENDEZ 5 MINUTES APRES AVOIR
DEBRANCHE L'ALIMENTATION AVANT
D'OUVRIR LA BOITIER
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH
Document No. D209-00-101-IS
Model
Issue 1
E2XL15F
Input
70V Line
70V Line
100V Line
100V Line
8 Ohm
8 Ohm
16 Ohm
16 Ohm
3) Rating & Marking Information
3.1. ATEX / IECEx / UKEx certification
The E2xL15 and E2xL25 loudspeakers comply with the
following standards:
EN IEC 60079-0:2018 / IEC60079-0:2017 (Ed 7):
Explosive Atmospheres - Equipment. General Requirements
EN IEC 60079-7:2015 +A1:2018 / IEC 60079-7:2018 (Ed. 5.1):
Explosive Atmospheres - Equipment Protection by Increased
Safety "e"
EN 60079-31:2014 / IEC 60079-31:2013 (Ed 2):
Explosive Atmospheres - Equipment Dust Ignition Protection
by Enclosure "t"
E2XL15:
E2XL25 :
20-08-22
E2XL25F
Wattage
Max I/P Volts
15
25
15
25
15
25
15
25
Standards
Ratings
Ex ec IIC T4 Gc Ta -20°C to +55°C
Ex tc IIIC T85°C Dc Ta -20°C to +55°C
Ex ec IIC T2 Gc Ta -20°C to +55°C
Ex tc IIIC 85°C Dc Ta -20°C to +40°C
Ex tc IIIC 100°C Dc Ta -20°C to +55°C
www.e2s.com
Tel: +44 (0)208 743 8880
70
70
100
100
10.95
14.14
15.49
20
Sheet 1 of 5

Advertisement

Table of Contents
loading

Summary of Contents for E2S E2xL15R

  • Page 1 INSTRUCTION MANUAL E2xL15R, E2xL15F, E2xL25R, E2xL25F Loudspeakers For use in Hazardous Locations E2XL15R / E2XL25R E2XL15F E2XL25F 1) Product Table Model Input Wattage Max I/P Volts E2xL15FV070 / E2xL15RV070 70V Line E2xL25FV070 / E2xL25RV070 70V Line E2xL15FV100 / E2xL15RV100 100V Line...
  • Page 2 Electric Code. E2XL15: 85°C E2XL25: 100°C 85°C (Only up to 40°C Ambient) European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D209-00-101-IS Issue 1 20-08-22 Sheet 2 of 5...
  • Page 3: Special Conditions Of Use

    They should only be fixed to services that can carry the weight of the unit. European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D209-00-101-IS Issue 1...
  • Page 4: Cable Connections

    55ºC Min. Rating of cables 90ºC 95ºC 100ºC 105ºC and cable glands European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D209-00-101-IS Issue 1 20-08-22 Sheet 4 of 5...
  • Page 5: Low Impedance Wiring

    For further detail, refer to schematic document D209-06-101 prior to opening the unit. European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D209-00-101-IS Issue 1...
  • Page 6 WRITTEN CONSENT. 05/08/2020 IMPRESS HOUSE R.N.POTTS STANDARDS MANSELL ROAD EUROPEAN SAFETY SYSTEMS LTD. ACTON DRAWING NUMBER LONDON W3 7QH SCALE SHEET ALTERNATIVE MATERIAL AS PER LATEST DATE OF ISSUE SHOWN ABOVE Ex N APPROVED DATE D209-06-101 WWW.E2S.COM NTS 1 05/08/2020 R.N.POTTS...
  • Page 7 WRITTEN CONSENT. 05/08/2020 IMPRESS HOUSE R.N.POTTS STANDARDS MANSELL ROAD EUROPEAN SAFETY SYSTEMS LTD. ACTON DRAWING NUMBER LONDON W3 7QH SCALE SHEET ALTERNATIVE MATERIAL AS PER LATEST DATE OF ISSUE SHOWN ABOVE Ex N APPROVED DATE D209-06-101 WWW.E2S.COM NTS 2 05/08/2020 R.N.POTTS...
  • Page 8: Eu Declaration Of Conformity

    Other Standards and Regulations EN 60529:1992+A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/IP67 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-062_Issue_I (E2x).docx - Page 1 of 2 - QAF_252_Issue_5...
  • Page 9 This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-062_Issue_I Quality Assurance Manager Date and Place of Issue: London, 22/08/2022 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-062_Issue_I (E2x).docx - Page 2 of 2 - QAF_252_Issue_5...
  • Page 10 Other Standards and Regulations EN 60529:1992+A2:2013 ‐ Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/IP67 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-103_Issue_A - Page 1 of 2 - QAF_252_Issue_5...
  • Page 11 This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC‐103_Issue_A Quality Assurance Manager Date and Place of Issue: London, 22/08/2022 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-103_Issue_A - Page 2 of 2 - QAF_252_Issue_5...

Table of Contents