Download Print this page

E2S E2xL15R Instruction Manual

For use in hazardous locations
Hide thumbs Also See for E2xL15R:

Advertisement

Quick Links

E2xL15R / E2XL25R
1) Warnings
• DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
• DO NOT OPEN WHEN ENERGISED
• POTENTIAL ELECTROSTATIC CHARGING
HAZARD - CLEAN ONLY WITH A DAMP
CLOTH
• HIGH VOLTAGE SHOCK HAZARD. WAIT 5
MINUTES AFTER REMOVING POWER
BEFORE OPENING THE ENCLOSURE
Avertissement:
• NE PAS OUVRIR UN PRESENCE
D'ATMOSPHERE EXPLOSIVE
• NE PAS OUVRIR ENERGIE
• DANGER POTENTIEL CHARGE
ÉLECTROSTATIQUE - NETTOYER
UNIQUEMENT AVEC UN CHIFFON HUMIDE
• HAUT TENSION, RISK DE CHOC.
ATTENDEZ 5 MINUTES APRES AVOIR
DEBRANCHE L'ALIMENTATION AVANT
D'OUVRIR LA BOITIER
2) Rating & Marking Information
2.1 ATEX / IECEx certification
The E2xL15 and E2xL25 loudspeakers comply with the
following standards:
EN60079-0:2012+A11:2013 / IEC60079-0: ed. 6.0 (2011-06)
EN60079-15:2010 / IEC60079-15: ed. 4.0 (2010-01)
EN60079-31:2014 / IEC60079-31:2013 ed. 2.0 (2013-11)
Certificate No.
DEMKO 06ATEX 0421554X
IECEx ULD 14.0012X
The E2xL15 loudspeaker is rated as follows:
II 3G Ex nA IIC T4 Gc Ta -20°C to +55°C
II 3D Ex tc IIIC T85°C Dc Ta -20°C to +55°C
The E2xL25 loudspeaker is rated as follows:
II 3G Ex nA IIC T2 Gc Ta -20°C to +55°C
II 3D Ex tc IIIC 85°C Dc Ta -20°C to +40°C
II 3D Ex tc IIIC 100°C Dc Ta -20°C to +55°C
_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH
Document No. D209-00-101-IS-SC
E2xL15R, E2xL15F, E2xL25R, E2xL25F Loudspeakers
For use in Hazardous Locations
E2xL15F
Issue C
20-01-21
INSTRUCTION MANUAL
CE Marking
2813
Zones, Gas / Dust Groups and Temperature
Classification
When connected to an approved system the E2X alarm horn
may be installed in:
Zone 2 explosive gas air mixture not likely to occur
in normal operation, and if it does, it will only exist
for a short time.
Zone 22 explosive dust air mixture not likely to occur
in normal operation, and if it does, it will only exist
for a short time.
May be used with gases in groups:
Group IIA
Group IIB
Group IIC
Having a temperature classification
(for Gas applications) of:
T1
450ºC
T2
300ºC
T3
200ºC (E2xL15 only)
T4
135ºC (E2xL15 only)
May be used with Dust types:
Group IIIA
Group IIIB
Group IIIC
Maximum Surface Temperature for Dust Applications:
100ºC
85ºC (E2xL25 only up to 40ºC ambient)
Installation must be carried out in compliance with the latest
issue of the following standards:
EN60079-14 / IEC60079-14: Explosive atmospheres -
Electrical installations design, selection and erection
EN60079-10-1 / IEC60079-10-1: Explosive atmospheres -
Classification of areas. Explosive gas atmospheres
EN60079-10-2 / IEC60079-10-2: Explosive atmospheres –
Classification of areas. Explosive dust atmospheres
sales@e2s.com
www.e2s.com
Sheet 1 of 6
E2xL25R
propane
ethylene
hydrogen / acetylene
combustible flyings
non-conductive dust
conductive dust
Tel: +44 (0)208 743 8880
Fax: +44 (0)208 740 4200

Advertisement

loading

Summary of Contents for E2S E2xL15R

  • Page 1 INSTRUCTION MANUAL E2xL15R, E2xL15F, E2xL25R, E2xL25F Loudspeakers For use in Hazardous Locations E2xL15R / E2XL25R E2xL15F E2xL25R CE Marking 1) Warnings • DO NOT OPEN WHEN AN EXPLOSIVE 2813 ATMOSPHERE IS PRESENT • DO NOT OPEN WHEN ENERGISED Zones, Gas / Dust Groups and Temperature •...
  • Page 2: Special Conditions Of Use

    Class II, Div 2, FG T5 Ta -20°C to +55°C Class II, Div 2, FG T6 Ta -20°C to +40°C _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH sales@e2s.com Tel: +44 (0)208 743 8880 www.e2s.com Fax: +44 (0)208 740 4200 Document No.
  • Page 3: Location And Mounting

    90ºC 95ºC 100ºC 105ºC and cable glands _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH sales@e2s.com Tel: +44 (0)208 743 8880 www.e2s.com Fax: +44 (0)208 740 4200 Document No. D209-00-101-IS-SC Issue C 20-01-21 Sheet 3 of 5...
  • Page 4: Cable Connections

    1/16” (1.58mm) must be provided through air and over surfaces between uninsulated live parts. Fig. 4 L15 Line in Terminals _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH sales@e2s.com Tel: +44 (0)208 743 8880 www.e2s.com Fax: +44 (0)208 740 4200 Document No. D209-00-101-IS-SC...
  • Page 5: Maintenance, Overhaul & Repair

    Fig. 9 L25 low Impedance Diagram Fig. 10 L25 Low Impedance Terminals _______________________________________________________________________________________________________________________________ European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH sales@e2s.com Tel: +44 (0)208 743 8880 www.e2s.com Fax: +44 (0)208 740 4200 Document No. D209-00-101-IS-SC...

This manual is also suitable for:

E2xl15fE2xl25rE2xl25f