Removing And Installing The Heat Sink - Gigabyte E263-Z30-AAD1 User Manual

Edge server – 2u up short depth amd epyc 9004 server system nvme/sata/sas
Hide thumbs Also See for E263-Z30-AAD1:
Table of Contents

Advertisement

3-3

Removing and installing the Heat Sink

Read the following guidelines before you begin to remove/install the heat sink:
• Always turn off the computer and unplug the power cord from the power outlet before installing
the heat sink to prevent hardware damage.
• Unplug all cables from the power outlets.
• Disconnect all telecommunication cables from their ports.
• Place the system unit on a flat and stable surface.
• Open the system according to the instructions.
WARNING!
Failure to turn off the server before you start installing components may cause serious damage. Do
not attempt the procedures described in the following sections unless you are a qualified service
technician.
Follow these instructions to remove/install the heat sink:
1.
Loosen the captive screws securing the heat sink in place in reverse order (6g5g4g3g2g1).
2.
Lift and remove the heat sink from the system.
3.
To reinstall the heat sink reverse steps 1-2 while ensuring that you tighten the captive screws in
sequential order (1g2g3g4g5g6) as seen in the image below.
• When installing the heat sink to CPU, use a Torx T20 screwdriver to tighten 6 captive nuts in
sequence as 1-6. The screw tightening torque: 13.5 ± 0.5 kgf-cm.
• To ensure the system operates properly, make sure the heatsink is seated on the processor firmly.
6 6
1 1
3 3
2 2
5 5
System Hardware Installation
- 25 -
4 4

Advertisement

Table of Contents
loading

This manual is also suitable for:

E263-z30

Table of Contents