Table of Contents BEFORE YOU BEGIN ........................4 ION-E100 ....................... 4 BOUT THE ..........................5 ARTS HARDWARE INSTALLATION ....................... 6 ......................6 QUIPMENT NSTALLATION CONNECTIONS ..........................7 ..........................7 RONT ANEL ..........................8 ANEL SERIAL PORT CONNECTIVITY ....................11 UNDERSTANDING LED STATUS ....................13 Normal Operation: .........................
Page 3
ION-E100 – User manual ANNEX A – CONFIGURATION PARAMETER REFERENCE ............32 ANNEX B – TROUBLESHOOTING GUIDE ..................35 ANNEX C – STATEMENT LIMITED WARRANTY ................36 Page 3 of 36 InterTest, Inc • 303 Route 94 • Columbia, NJ 07832 • 908-496-8008 • sales@intertest.com • www.intertest.com...
1 Before you begin 1.1 About the ION-E100 The ION-E100 single port encoder delivers high quality H.264 video encoding to the video surveillance market. It is an embedded, high-performance digital video encoder, capable of encoding an analog camera input using multiple profiles at a combined 90 images per second (NTSC/PAL) at 4CIF resolution.
Note: The product serial number label helps the Ionodes product support team identify your device and its factory configuration in the event that your ION-E100 or its com- ponents require service. The label is attached on the underside of the enclosure.
2 Hardware Installation 2.1 Equipment Installation The ION-E100 can be placed on a flat surface, such as a desktop, or mounted via the available mounting holes. When installing the ION-E100, position the unit to allow for cable clearance at the front and rear of the unit.
ION-E100 – User manual 3 Connections Familiarize yourself with the ION-E100 front and rear panels before connecting any equipment to the unit. The ION-E100 offers a single analog video input and associated I/Os and audio connections. 3.1 Front Panel ...
– User manual ION-E100 3.2 Rear Panel Terminal Bloc Header Terminal Bloc Header This header connector is used to connect the supplied Terminal Bloc Socket which provides the interface to serial port, I/O and power connections. Below is a detailed view of this Terminal Bloc Socket: Relay Output Digital Input Pins #1 &...
Page 9
ION-E100 – User manual The pin out description of the Terminal Bloc Socket is as follows: Number Description Direction RL (Relay) RL (Relay) I1 (Digital Input 1) I2 (Digital Input 2) 12V supply Ground AUDIO IN / OUT 3.5 mm jack which can be used to connect both an audio input and an audio output source.
Page 10
ETHERNET / PoE This is the ION-E100 network port. Please use a straight RJ45 (cat. 5 or 6) network cable. The ION-E100 accepts a Power-Over-Ethernet (PoE) compliant power source if needed.
These protocols are standards for binary data exchange between DTE and DCE equipments. To connect serial equipment to an ION-E100 using RS-422/485 4-wire configuration, use the following steps: 1. Connect twisted pair cables to the Terminal Bloc Socket located on the front panel of the device.
Page 12
2. To create the positive data signal, please connect Rx+ and Tx+ pins together on the Terminal Bloc Socket. 3. To ensure proper connection between RS-485 2-wire serial equipment and the ION- E100, use the following scheme: Equipment Serial Port ION-E100 Serial Port Data + Data + Data - Data - Page 12 of 36 InterTest, Inc •...
Firmware update in progress – LED is flashing slowly red/yellow Note: Under normal operation, the ION-E100 takes up to 1-2 minutes to boot up. Page 13 of 36 InterTest, Inc • 303 Route 94 • Columbia, NJ 07832 • 908-496-8008 • sales@intertest.com • www.intertest.com...
6.1 Network Configuration By factory default, the ION-E100 is configured in DHCP. If you are not using a DHCP server it will automatically allocate itself an APIPA (Automatic Private IP Addressing) address in the range 169.254.0.1 to 169.254.255.254 with subnet mask 255.255.0.0.
Page 15
ION-E100 – User manual Once your device is installed on your network and powered up, launch ICT from any computer on the network and the following window will be displayed: The ICT supports 2 ways to discover a device. The first way doesn’t need any configuration and uses the Bonjour discovery protocol.
Page 16
– User manual ION-E100 To configure the Unicast Discovery, add one or more IP address ranges. The Unicast Discovery tries to reach a device at a specific IP address in the configured ranges. The discovery can be a long process if the range of IP addresses is huge and the device is at the end of the range. To accelerate the discovery, add several small ranges of IP addresses.
Page 17
ION-E100 – User manual If no DHCP server was able to assign an IP address to an ION-E100, it will appear in the ICT device list with an APIPA address (169.254.*.*). If an ION-E100 displays an APIPA address it must be configured with a valid IP address before it can be remotely configured by selecting the ‘’Assign IP address’’...
– User manual ION-E100 Once the IP information is set, the Silverlight web application served by the ION-E100 can be launched from the ICT or directly in your web browser by typing the device’s IP address in the address bar. You can start to use your networked video management system for final system configuration or you can configure advanced parameters using the ION-E100’s web based...
ION-E100 – User manual Setting up the NTP server Under the Configuration section, select the Network tab and set the proper NTP server address under the NTP Configuration header. Configuring Video Parameters You may disable any of the three (3) video encoder streams (Primary H.264, Secondary H.264 and MJPEG).
ION-E100 – User manual 7 Performing a Firmware Update This section describes how to update your ION-E100 to newer firmware versions from the web application. 1. Navigate to your device’s web application using your favorite web browser. 2. Click on the Maintenance tab.
ION-E100 7.1 Batch Firmware Update This section describes how to perform a batch update of multiple ION-E100 devices to newer firmware versions from the ICT. The batch firmware update works by starting a firmware update session. Only one session at time is allowed and only 20 devices can be selected by session.
Page 23
ION-E100 – User manual To start a firmware update session, choose the “.iof” file corresponding to the new firmware by clicking to the “Select File …” button. Once selected, click to the “Start” button. Once started, the “Firmware Update Session” window shows the progress of the firmware update.
Page 24
– User manual ION-E100 If closed, the progress of the current session can be followed by reopening the “Firmware button from the “Tools” toolbar. Update Session” window by clicking the Once done, clear the current session from the “Firmware Update Session” window and restart a new session if needed.
ION-E100 – User manual 8 Recording on the Edge In most setups, the ION-E100 is used to stream video and/or audio to an ION-R100 or to a central video management system (VMS). From there, the streams can be viewed «live» (in real time), recorded or both.
Page 26
– User manual ION-E100 The recording in the ION-E100 is configured using only a few parameters: Enabled: Determines whether recording on the edge is active. Current Recorder State: Provides information of the current state of the recorder. Possible states include Idle, Rebuilding Index and Active.
Page 27
NVR Detection Method: Determines how the ION-E100 is to detect when it loses its connection to the video management server. Server Ping: The ION-E100 actively polls the IP address of the server for a reply to ensure that the address is present on the network. This method is independ- ent from the type of video management server.
The associated audio input will now be recorded simultaneously to its parent video input. 8.3 Retrieval / Management of Video Clips Recorded video on the ION-E100 can be retrieved through the device’s web application. To view and manage the list of recorded video clips: ...
ION-E100 – User manual 8.3.1 Displaying Clips When you select a video input, the web application displays a list of dates with video recorded from that input. To display the list of recorded video clips for a specific date, simply click on the date.
– User manual ION-E100 To lock one or more video clips, you must first select each clip by clicking on the check box on its right. If you want to select all the video clips for a day, you can also click on «Select All»...
Point-to-point connections between an ION-E100 and an ION-R100 can be configured using the device’s web application. In the ION-E100’s web application, in the Configuration section, go to the Video In tab and select «video input 1». Scroll down all the way to the bottom of the configuration page. The last 3 sections are named Point to Point 1, 2 and 3.
Page 32
– User manual ION-E100 Annex A – Configuration Parameter Reference 1. Video Input Configuration Hue - The hue filter allows you adjust the hue of an entire image. Hue is the color reflected from or transmitted through an object. It is measured as a location on the standard color wheel.
Page 33
ION-E100 – User manual Enabled – This parameter allows you to enable or disable a video input. 2. Video Codec Configuration (H.264 & JPEG) Enabled – This parameter allows you to enable or disable a video codec. ...
Page 34
– User manual ION-E100 The visual difference is much greater between baseline and main then between main and high. Also, the differences appear only when the visual quality begins to degrade (ex: when the quality begins to degrade on baseline profile, switching to main profile will restore some of the image quality).
Page 35
Make sure the GREEN LED on the RJ45 connector is lit. If it is not lit, verify the network connectivity with the network switch. Dynamic discovery of the ION-E100 requires multicast networking to be supported by your network and switch equipment. (Bonjour protocol) Page 35 of 36 InterTest, Inc •...
Page 36
The warranty period for an ION-E100 is a specified, fixed period commencing on date of billing by Ionodes for the Product. If a valid proof of billing cannot be found, the warranty may be void by Ion- odes Inc. or measured from the date the ION-E100 has shipped from a Ionodes Depot center based on its serial number.
Need help?
Do you have a question about the ION-E100 and is the answer not in the manual?
Questions and answers