Heat & Glo SL-5F-IFT Installation Manual page 62

Hide thumbs Also See for SL-5F-IFT:
Table of Contents

Advertisement

NO LAVA ROCK IN BURNER SLOT
(INSIDE DASHED LINE)
Figure 11. Rock Jig Removed
Log #5 (SRV2033-720): Log #5 is used twice in this log set. The left log is located by placing the "Y-Shaped" end on the
locating grooves of Log #3 and setting the other end on the flat area of Log #1. See Figure 9 to reference locations of flat areas
and grooves. Figure 12 shows the left side Log #5 in position. The right side Log #5 is located by placing the "Y-Shaped"
end on the locating grooves of Log #1 and setting the other end on the right side log #2. See Figure 12 and Figure 13. The
log should be approximately 1-1/2 inch from the end of Log #2. See Figure 14.
Figure 13. Log #5 (2nd of 2)
Figure 15. Logs-550F Installed
62
Heat & Glo • SL-5F-IFT, SL-7F-IFT Installation Manual • 2638-980 Rev. H • 6/22
4 4
3 3
Figure 12. Log #5 (1st of 2)
Figure 14. Log #5 Placement
LOCATING GROOVES
LOCATING GROOVES
5 5
1 1
2 2
2297-983F