Table of Contents

Advertisement

Quick Links

Models:
SL-550BE-M-IPI
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.

• What to do if you smell gas

- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10
Owner's Manual
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
Installation and Operation
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo SL-550BE-M-IPI

  • Page 1: What To Do If You Smell Gas

    Technologies suggests NFI certifi ed or factory trained This appliance is only for use with the type(s) of gas indicated professionals, or technicians supervised by an NFI on the rating plate. certifi ed professional. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 2: Congratulations

    BTUH: 00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 3: Table Of Contents

    F. Wall Switch Installation for Fan (Optional) ... . 53 6 Termination Locations A. Vent Termination Minimum Clearances ....21  Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 4 D. Contact Information ......76  = Contains updated information. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 5: Limited Lifetime Warranty

    B. Limited Lifetime Warranty Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 6 B. Limited Lifetime Warranty (continued) Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 9: User Guide

    fi re or injury. - Adjustable safety gate. DECORATIVE DOORS (NOT SHOWN) SECTION 2.D. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 14.F. MANTEL FAN KIT SECTION 2.C HEARTH Figure 2.1 General Operating Parts Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 10: Fan Kit (Optional)

    WARNING! Risk of Fire or Asphyxiation! DO NOT op- erate fi replace with fi xed glass assembly removed. Figure 2.2 Clear Space Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 11: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 12: After Fireplace Is Lit

    Is it normal to see the pilot fl ame burn turned off. Some optional control systems available with IPI models may allow pilot fl ame to continually? remain lit. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 13: Maintenance And Service

    • Carefully set fi xed glass assembly in place on fi replace. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    • Verify that there is not a short in fl ame sense circuit by checking continuity between pilot hood and fl ame sensing rod. Replace pilot as necessary. (IPI only) Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 15 Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 16: Installer Guide

    IN CEILING JOISTS FRAMING/HEADER (SECTION 8.C) (SECTION 5.B) OPTIONAL WALL SWITCH MANTEL AND MANTEL LEG (SECTION 5.E, 13.B) SURROUND HEARTH EXTENSION GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 17: Design And Installation Considerations

    Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300ºF minimum continuous exposure  rating) One 1/4 in. female connection (for optional fan). Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 18: Framing And Clearances

    E Min. F Min. 59-1/2 62-1/4 16-1/4 48-1/2 68-3/4 15-1/16 7-1/2 7-1/8 See Section 5.E for SL-550BE-M-IPI Alcove Installation 1067 1511 1117 1581 1232 1746 Figure 5.1 Appliance Locations Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 19: Constructing The Appliance Chase

    16-1/4 SL-550BE-M-IPI * Adjust framing dimensions for interior sheathing (such as sheetrock) ** Adjust framing dimension for clean fi nishing technique. See Section 13.D. Figure 5.2 Clearances to Combustibles Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 20: Mantel And Wall Projections

    1/2 in. THICK WALL 3-1/2 in. SHEATHING Note: Clearance from opening to perpendicular wall. Figure 5.6 Wall Projection (Acceptable on one side of opening) 1/2 in. NON-COMBUSTIBLE ZONE Figure 5.4 Non-Combustible Zone Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 21: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 22 Figure 6.3 Minimum Clearances for Termination requirements. CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 23: Vent Information And Diagrams

    76 to 152 DVP12A 3 to 12 76 to 305 DVP12MI 3 to 12 76 to 305 DVP24MI 3 to 24 76 to 610 Figure 7.2 DVP Pipe Effective Length Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 24: Use Of Flex Vent

    However, 1 in. the vent attachment point and the fi restop CLEARANCE location are considered to be supports. Figure 7.3 Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 25: Vent Diagrams

    Note: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 7.3). Figure 7.4 Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 26 fi rst elbow. • When using DVP-TB1 termination cap on top vented fi replaces, a three foot minimum vertical vent section is required before installing fi rst elbow. Figure 7.5 Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 27 • When using SLP-HRC-SS and SLP-HRC-ZC- SS termination caps on top vented fi replaces, a one foot minimum vertical vent section is required before installing fi rst elbow. Figure 7.6 Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 28 fl ame height. If the vent confi guration has a total vertical of 15-60 feet, an exhaust restrictor may be needed. The exhaust restrictor can be located in the appliance manual bag. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 29 Note: There MUST be a 25% reduction HORIZONTALLY in total H when using fl ex vent except when using the simple up and out installation (see Figure 7.3). Figure 7.10 Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 30 Note: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 7.3). Figure 7.11 Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 31 Figure 7.12 Rear Vent - Horizontal Termination = 9 in. (229 mm) Maximum One 45º Elbow Note: Use DVP Series components only. Figure 7.13 Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 32 6 ft. 1.8 m 13-1/2 ft. 4.1 m HORIZONTALLY MAX. = 7-1/2 ft. (2.3 m) MAX. = 13-1/2 ft. (4.1 m) MAX. = 40 ft. (12.2 m) Figure 7.15 Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 33 6-1/2 ft. 2.0 m 3 ft. 914 mm H MAX. = 6-1/2 ft. (2 m) V + H+ H MAX. = 40 ft. (12.2 m) INSTALLED HORIZONTALLY Figure 7.17 Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 34 14-1/2 ft. 4.4 m MAX. = 7-1/2 ft. (2.3 m) MAX. = 14-1/2 ft. (4.4 m) MAX. = 40 ft. (12.2 m) Note: Use DVP Series components only. Figure 7.18 Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 35: Coaxial To Colinear Venting

    CAUTION! DO NOT use any fl ue restrictor when vent- ing with the DV-46DVA-GCL adapter and LINK-DV30B kit. This may result in poor fl ame appearance, sooting, pilot malfunction, or overheating. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 36: Rear Vent

    10 ft. 3.05 m 0 ft. 0 mm Minimum 10 ft. 3.05 m Maximum 40 ft. 12.2 m 2 ft. 610 mm Maximum 40 ft. 12.2 m Figure 7.21 Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 37: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 38: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 39: Install Attic Insulation Shield

    • Bend all tabs inward 90º around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 40: Appliance Preparation

    The heat shield must remain in the vertical position. 2 SCREWS Figure 9.3 Replace the two screws as shown. Figure 9.6 Remove the insulation from the outer vent pipe. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 41: Rear Vent

    Use two self- tapping screws to secure gasket to outer wrap. Figure 9.9 Cut the metal retaining band and fold the sides out. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 42: Securing And Leveling The Appliance

    • Secure the appliance to the framing by using nails or screws through the nailing tabs. • Secure the appliance to the fl oor by inserting two screws through the pilot holes at the bottom of the appliance. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 43: Installing Vent Pipe (Dvp And Slp Pipe)

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 44: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 45: Secure The Vent Sections

    Figure 10.10 Rotate Seams for Disassembly connection point to appliance. Figure 10.11 Align and Disassemble Vent Sections Figure 10.8 Securing Vertical Pipe Sections Figure 10.9 Securing Horizontal Pipe Sections Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 46: Install Decorative Ceiling Components (Slp Only)

    fl aps and the roof. Figure 10.13 WARNING! Risk of Fire! Clean out ALL materials from inside the support box and complete the vertical vent run and termination. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 47: Install Metal Roof Flashing

    See Figure 10.15. • Caulk the overlap seam of any exposed pipe sections  that are located above the roof line. Figure 10.17 Assembling the Storm Collar Around the Pipe Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 48: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.19. Figure 10.19 Wall Thimble Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 49: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 50: Gas Information

    fl exible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 51: Electrical Information

    Remove batteries before using the transformer, and unplug the transformer before installing the batteries. Battery polarity must be correct or module damage will occur. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 52 MODULE 3 VAC TRANSFORMER ORANGE 3 VAC WHITE GROUND TO FIREPLACE PLUG IN CHASSIS WIRES BATTERY PACK (TO BROWN) REMOTE PLUG IN VALVE Figure 12.2 IntelliFire Ignition Wiring Diagram with Remote Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 53: Junction Box Installation

    Figure 12.4 Junction Box Wired to Wall Switch or BC10 (1/4 in. male) as shown. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 54: Finishing

    TOP SLOT Figure 13.2 Step 3. Crease fl aps on left and right sides of splatter guard Figure 13.5 using the scored line as the guide. See Figure 13.3. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 55 Carefully grab splatter guard on or near the vertical center on the left and right sides. Pull outward gently, but fi rmly, Figure 13.8 taking care not to tear or remove the inserted tabs. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 56: Mantel And Wall Projections

    3 FT. MAXIMUM Note: Clearance from opening to perpendicular wall. Figure 13.13 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) NON-COMBUSTIBLE ZONE Figure 13.15 Non-Combustible Zone Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 57: Facing Material

    FINISH WALL MATERIAL MAY BE COMBUSTIBLE - TOP AND SIDES 0 IN. 0 IN. 0 IN. HIGH TEMPERATURE SEALANT (300° F/149° C MIN.) TOP AND SIDE SEAL JOINT Figure 13.16 Noncombustible Facing Diagram Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 58: Doors

    (Includes 1/8 in. opening each side of door) Finishing material between 1 and 4 inches thick. Refer to Table 1 for X and Y dimensions. Figure 13.20 Operable Hinge Door (Halston) Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 59: Appliance Setup

    RHEOSTAT SWITCH TEMPERATURE SENSOR Figure 14.1 Fan Wiring with Rheostat VARIABLE SPEED SWITCH JUNCTION BOX TEMPERATURE SENSOR SWITCH BLUE Figure 14.2 Detail of Fan Wiring with Rheostat Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 60: Rock Media Instructions

    3. Hand bend the ten tabs on the rock media jig as shown in Figure 3. Place the jig over the burner opening. Figure 3. Rock Media Tray and Rock Placement Jig in Place. 2185-936B 9/10 Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 61 DO NOT block burner ports with glass rock media. Delayed ignition may occur. Fireplace will not function properly. Figure 5. Removing Rock Media Jig. NO GLASS ROCK MEDIA IN BURNER OPENING Figure 6. Burner Opening. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 62: Fixed Glass Assembly

    • Use non-combustible materials to cover the gap between Models the sheet rock and the appliance (when applicable to SL-550BE-M-IPI 3/16 in. 1/4 in. model). Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 63: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. D. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 2.7. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 64 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 65: Reference Materials

    Ø Ø GAS LINE ACCESS ELECTRICAL ACCESS Location Inches Millimeters Location Inches Millimeters 16-3/8 27-3/16 25-3/4 12-7/8 15-7/8 3-1/2 6-5/8 6-7/8 34-3/8 2-3/16 36-1/2 8-3/4 Figure 16.1 Appliance Dimensions Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 66: Vent Components Diagrams

    (254 mm) 14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 67 79 mm 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 16.3 DVP vent components Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 68 Cap Shield 13-7/8 in. 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Figure 16.4 DVP vent components Cap Shield Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 69 1 in. (25 mm) 8-3/4 in. (222 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) 1-5/8 in. (41 mm) DVP-FBHT FireBrickTermination Cap DVP-HPC High Performance Cap Figure 16.5 DVP vent components Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 70 10-1/2 in. (381 mm) 267 mm 10-7/8 in. 276 mm SLP-HRC-SS SLP-HRC-ZC-SS HORIZONTAL TERMINATION CAP DVP-TB1 DVP-TB1 SL-2DVP SLP90 ASSEMBLY DVP-TB1 HORIZONTAL TERMINATION CAP Figure 16.7 SLP Series Vent Components Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 71 2 - 12 51 - 305 SLP-FLEX-2 SLP-FLEX-3 SLP-FLEX-5 1524 SLP-FLEX-10 3048 SLP-HVS SLP-FS SLP-WS Horizontal Pipe Ceiling Firestop Wall Shield Firestop Support Figure 16.8 SLP Series Vent Components Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 72 Cathedral Ceiling Snorkel Termination Cap Support Box-Black Termination Cap DVP-2SL SL-2DVP Adapter Adapter SLP-DCF-BK SLP-WT-BK Ceiling Firestop Wall Thimble-Black Black SLP-FLEX-TRAP Horizontal Termination Kit Figure 16.9 SLP Series Vent Components Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 73 16-11/16 IN. (336 mm) 424 mm (424 mm) 12 IN. (305 mm) COAXIAL to COLINEAR VENTING LINK-DV30B DVP-2SL DV-46DVA-GCL Flex Liner Kit Adapter Coaxial/Colinear Appliance Connector Figure 16.10 Vent Components Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...
  • Page 74: Service Parts List

    5647340, 5890485, 5941237, 5947112, 5996575, 6006743, 6019099, 6053165, 6145502, 6170481, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729 or other U.S. and foreign patents pending. 2000-945 Printed in U.S.A. - Copyright 2010 Heat & Glo • SL-550BE-M-IPI • 2188-900 Rev. H • 11/10...

Table of Contents