Redback® A 4505C Lockdown Timer with Network Access

3.0 NETWORK ACCESS

The Redback® A 4505C has been upgraded from previous versions to now include access via a network connection. The
unit is connected with the addition of the Redback® A 4498 Network Connection Pack. With the upgraded PC software
all the event timing and audio file selection can be adjusted remotely.
Note: Audio files cannot be transferred via this connection. All audio files must be loaded onto the supplied Micro SD card
via the PC software. These files are stored in a Library on the SD card and can then be selected remotely.
Figure 3.1 below demonstrates how to connect the timer to a network via the Redback® A 4498 Connection Pack. The
pack includes a serial to ethernet converter, a proprietry adaptor board, a DC power lead and a short CAT6 lead for con-
nection between the A 4505C and the Adaptor board. The Serial to Ethernet Converter requires some configuration which
is outlined in the A 4498 instruction manual.
Once the Serial To Ethernet Converter setup is complete and all required connections made, the unit should now be acces-
sible via the PC software. Refer to the supplied Software Programming Guide for more information.
Note: An IT administrator or someone experienced with network protocols wil be required to setup the net-
work access.
IMPORTANT NOTE
Ensure power is switched o when
adjusting DIP switches. New
24V
24V
settings will be e ective when
power is switched back on.
DC In
DC In
DIP Switches
1
2
3
4
5
6
7
8
To Wall Plate
-
+
1 2 3 4 5 6 7 8
Fig 3.1 Connecting the timer to a network via the Redback® A 4498 Connection Pack
14
Redback® Proudly Made In Australia
Common
24V Out
Cancel
Fire
Lockdn
Bell
Mic
Trigger
Trigger
Trigger
Trigger
Volume
To Paging
Outputs limited to 120mA maximum current draw
Console
Connect to the red RJ45 port.
Proprietry adaptor board
DC Power Lead
(Supplied)
Fire
Lockdown
Bell
24V Out
24V Out
24V Out
ON
OFF
Network
Battery
Adapter
Backup
(Use 3V CR2032 Battery Only)
Serial Device Server
(Altronics D 4231)
L
lock/Fire
Bell
Music
V/Over
Prebell
Level
Level
Level
Level
Level
CR2032
R
Audio
Backup Battery Holder
Out
Connect to Ethernet
network
www.redbackaudio.com.au
Manufactured in Australia
By Altronic Distributors Pty. Ltd.
www.redbackaudio.com.au