Override At Startup - Datasensing SH4 STANDARD MUTING Product Reference Manual

Safety light curtains
Table of Contents

Advertisement

FUNCTIONS

Override at Startup

To activate override RESTART button must be pressed (signal LOW) between 5 and 9 sec-
onds after startup and kept pressed for more than 5 seconds for override to start.
At least one beam must be intercepted for override request to be accepted.
OPTICAL PATH
OVERRIDE STATUS
OVERRIDE CONTACT
POWER STATUS
Override ends on any of the following conditions (OR):
58
SH4 STANDARD MUTING
9s > t > 5s
Figure 46: Override at startup timings
TEST button press/release
2s after all beams are free
After 10min timeout
NOTE: External lamp flashes when Override is active and user interface
visualizes Override Active signals (see "Override Active" on page 63).
NOTE: When Automatic Restart is selected OSSDs remains activated after
Override ends.
NOTE: When Manual Restart is selected restart contact must be open and
closed again to reactivate OSSDs.
2s
> 5s
FREE
INTERCEPTED
ON
OFF
CLOSED
OPEN
ON
OFF