SH4-XX-XXXX-SM-8 Dip Switches Settings

Muting Direction

SH4-XX-XXXX-SM-8-5 Dip Switches Settings

Override Trigger
Muting Direction
Muting Timeout
Muting Filter (100ms)
1. When Restart Mode is Manual a RESTART signal is requested at the end of Override sequence.
FUNCTION
Partial Muting
Code
EDM
Restart Mode
Muting Timeout
Muting Filter
FUNCTION
1
Code
EDM
Restart Mode
DIP
SETTINGS (DEFAULT IN BOLD)
OFF: Total Muting
1
ON: Partial Muting
OFF - OFF: no code
OFF - ON: code 1
2 - 3
ON - OFF: code 2
ON - ON: not used
OFF: Disabled
4
ON: Enabled
OFF: Automatic
5
ON: Manual
OFF: T
6
ON: L
OFF: 10 min
7
ON: infinite
OFF: 100ms muting filter
8
ON: no muting filter
DIP
SETTINGS (DEFAULT IN BOLD)
OFF: Level
1
ON: Edge
OFF - OFF: no code
OFF - ON: code 1
2 - 3
ON - OFF: code 2
ON - ON: not used
OFF: Disabled
4
ON: Enabled
OFF: Automatic
5
ON: Manual
OFF: T
6
ON: L
OFF: 10 min
7
ON: infinity
OFF: 100ms muting filter
8
ON: no muting filter
DIP SWITCHES
(Configuration Failure if set)