Alignment Of The Bus; Tolerance Position Pantograph - ABB HVC 150P User Manual

Table of Contents

Advertisement

3. Alignment of the bus

It is important that the Pantograph is in the right position in relation to the bus, so that the
Pantograph can make good physical contact with the power charge connection rails on the
roof of the bus.
For most electric hybrid and/or full electric bus, the front wheelbase is exactly below the power
charge connection rails on the roof of the bus. Check the technical specifications of the used
electric hybrid / full electric bus for the correct position of the power charge connection rails.
Reference position of the connection rails directly above the front wheelbase.

3.1. Tolerance position Pantograph

In general the bus has a certain freedom degree to position under the Pantograph:
➢ Driving direction: +/- 300 mm, 600 mm in total;
➢ Sideways: +/- 250 mm, 500 mm in total;
➢ Height: 1600 mm.
Document: v0.4 / Document No.: 6AGA000008-0607-EN | Date: 22-05-2019