Installation

Welder Specifications

Primary (input) volts
Maximum Output
Phase
Frequency
Recommended Circuit Breaker
Extension Cord Recommendations
Generator Requirements
CSA Rated Output and Duty-Cycle
Dimensions
Weight
Recommended Electrode Diameter

Site Selection

BE SURE TO LOCATE THE WELDER ACCORDING TO THE FOLLOWING GUIDELINES:
In areas free from moisture and dust;
In areas with ambient temperature between 30° to 90°F;
In areas free from oil, steam and corrosive gases;
In areas not subjected to abnormal vibration or shock;
In areas not exposed to direct sunlight or rain;
Place at a distance of 12" or more from walls or similar obstructions that could restrict natural air flow for
cooling.

Power Source Connection

Before you make any electrical connection, make sure that the ON/OFF SWITCH (12) is OFF, power supply voltage
and frequency available at site are those stated in the ratings label of your welder.
The main power supply voltage should be within ±10% of the rated main power supply voltage. Too low a power
supply voltage may cause poor welding performance. Too high a power supply voltage will cause components to
overheat and possibly fail. The welder outlet must be:
Correctly installed, if necessary, by a qualified electrician;
Correctly grounded (electrically) in accordance with national and local regulations;
Connected to an electric circuit that is rated for sufficient amperage per the ratings label of your welder.
Refer to the ratings label and be sure to set the machine so that amperage draw will not exceed the rated limits.
If you are unsure of any of the above, have your outlet inspected by a qualified electrician before using the welder.
NOTE:
Periodically inspect INPUT POWER CABLE (13) for any cracks or exposed wires. If it is not in good condition,
have it repaired by a Service Center.
Do not cut off the grounding prong or alter the plug in any way and do not use any adapters between the
welder's INPUT POWER CABLE and the power source receptacle.
Do not violently pull the INPUT POWER CABLE to disconnect it from power outlet.
10
120VAC/240VAC
120V - 80A (DC output only)
240V - 180A (DC output only)
Single
50/60Hz
120V - 30A time-delay (slow-blow) breaker for maximum
performance (20A minimum breaker size)
240V - 50A time-delay (slow-blow) breaker for maximum
performance (30A minimum breaker size)
Refer to the ratings label and set the output amperage so that the
listed input amperage is not exceeded
3 conductor #10AWG (240V) or #12AWG (120V) or larger up
to 25 ft.
120V - Minimum 4,000W continuous output with no low-idle
function (or low-idle off), 5% THD Max
240V - Minimum 10,500W continuous output with no low-idle
function (or low-idle off), 5% THD Max
Refer to the data plate of your machine and the DUTY-CYCLE
section of this manual, page 14
15" (380mm) X 6.25" (159mm) X 10.75" (273mm)
11.9 lbs. (5.4 kg)
Up to 1/8" (120V) - Up to 5/32" (240V)
WWW.FORNEYIND.COM