Bosch 23-15-2055 Manual page 210

Pegasus pedelecs with bosch purion on-board
Table of Contents

Advertisement

Symptom
Cause
Fluid is leaking from the
battery.
There is an unusual
smell.
Fumes are emitted from
the battery.
Table 61: Error solution for battery
9.2.5
On-board computer errors
Symptom
Cause
No data is shown on the
The battery charge level may be
monitor when the On-Off
insufficient.
button (battery) is
pressed.
Is the power switched on?
Is the battery charged?
Is the connector fitted to the power
cable correctly?
A component may be connected which
the system is unable to recognise.
The gear level is not
The gear level is only shown if the
shown on the display
electronic gear shift is used.
screen.
The settings menu cannot
The product is designed in such a way
be opened while you are
that the settings menu cannot be
pedalling.
opened if the system detects that
someone is riding the pedelec. This is
not a malfunction.
The time display is
The battery in the on-board computer
flashing "0:00"
has come to the end of its service life.
Table 62: Display error solution
9.2.6
Lighting does not work
Symptom
Cause
Front lamp or rear lamp
The default settings in the electric drive
does not go on, even
system have probably been configured
when the switch is
incorrectly.
pressed.
The light is defective.
Table 63: Lighting error solution
MY23P01 - 22_1.0_21.10.2022
Troubleshooting, fault clearance and repair
Remedy
 Observe all the warnings in Section 2 Safety.
1
Remove from the battery immediately.
2
Contact the fire service immediately.
3
Observe all the warnings in Section 2 Safety.
1
Remove from the battery immediately.
2
Contact the fire service immediately.
3
Observe all the warnings in Section 2 Safety.
Remedy
 Charge the battery.
 Press the On-Off button (battery) to switch the power on.
 If the battery is fitted to the pedelec and is being charged, it
cannot be switched on. Interrupt charging process.
1
Check that the power cable connector has not been
disconnected.
2
Contact your specialist dealer if this is not the case.
 Contact your specialist dealer.
1
Check whether the power cable plug has been disconnected.
2
Contact your specialist dealer if this is not the case.
1
Stop pedelec.
2
Change settings when stationary only.
 Replace on-board computer battery.
Remedy
1
Take pedelec out of service immediately.
2
Contact specialist dealer.
209

Advertisement

Table of Contents
loading

Table of Contents