Components
Frequency
6 months
Chain/cassette/
pinion/chainring
Chain guard/
6 months
spoke guard
Bottom bracket
6 months
axle/crank
6 months
Pedals
6 months
Shifter
6 months
Shift cables
6 months
Front derailleur
6 months
Rear derailleur
6 months
On-board
computer
6 months
Control panel
6 months
Tachometer
6 months
Cabling
6 months
Rechargeable
battery
6 months
Battery mount
6 months
Motor
6 months
Software
MY23P01 - 22_1.0_21.10.2022
Description
Inspection
Tests
Check for damage
Check for
damage
Check for damage
Check for
damage
Check mount
Check mount
fastening
fastening
Check mount
Check mount
fastening
fastening
Check mount
Check mount
fastening
fastening
Check for damage
Check for
damage
Check for damage
Check for
damage
Check for damage
Check for
damage
Electric drive system
Check for damage
Check for
damage
Check control panel
Check for
for damage
damage
Calibration
Speed meas-
urement
Visual inspection
Visual inspec-
tion
First examination
see Section
Assembly
Firmly in position,
Check mount
lock, contacts
fastening
Visual inspection
Check mount
and mount
fastening
Check version
Check software
version
Maintenance
Acceptance Rejection
Drive/gear shift
...
O.K.
...
O.K.
...
O.K.
...
O.K.
...
O.K.
...
O.K.
...
O.K.
...
O.K.
...
O.K.
...
O.K.
...
O.K.
...
O.K.
...
O.K.
...
O.K.
...
O.K.
...
In latest
version
Inspection and maintenance
Criteria
Measures if rejected
Damage
Refasten if necessary
or replace as speci-
fied in parts list
Damage
Replace as specified
in parts list
Loose
Retighten screws
Loose
Retighten screws
Loose
Retighten screws
Loose and
Adjust shift cables;
defective
new shift cables if
necessary
Gear shift diffi-
Adjust
cult or not
possible
Gear shift diffi-
Adjust
cult or not
possible
No screen,
Restart, test battery,
defective
new software or new
screen display
on-board computer,
decommissioning,
No response
Restart; contact
control panel manu-
facturer, new control
panel
Pedelec travel-
Take pedelec out of
ling 10% too
service until the
fast/slow
source of the error is
found
Failure in
New cabling
system,
damage,
kinked cables
Error message Contact battery manu-
facturer; take out of
service, new battery
Loose; lock
New battery mount
doesn't close,
no contacts
Damage, loose Refasten motor,
contact motor manu-
facturer, new motor;
take out of service
Not latest
Import update
version