Stop charging:
7. If there is another bus connected to the charger that requires bulk charging the
charger will stop the preconditioning and automatically switch to the bus that
requires bulk charging.
8. The preconditioning will continue in a 20 min loop between all the connected bus
until the charge session is stopped. This can be done manually by either pushing
the stop button on the depot charge box or the stop button on the bus (not
available on every bus).
9. If the stop button is pressed and there is another vehicle connected that requires
bulk charge or preconditioning, the charging will automatically switch to the next
bus in line and continue the charge session.
10. When the charging is stopped, the connector is unlocked by the vehicle for CCS.
11. Take the connector out of the vehicle and put it back in the connector holder on
the depot charge box.
3.3

Emergency stop

If there is an emergency:
1.
Push the emergency stop button.
The Charger stops the operation and the LED beacon from each connected Depot
Charge Box will be red.
2. Contact the Site operator.
Document: v0.6 / Document No.: 6AGA000008-0102-EN | Date: 22-05-2019
NOTICE
Session end
Charging will stop without user interaction:
When the EV indicates to the charger that charging is
completed.
When the charger completed the bulk charge.
If the battery is not full, a new charge session can be started.
NOTICE
Stop by emergency button
The charger stops the charge session when the emergency
stop is pushed. Only push the emergency stop if there is an
emergency!
NOTICE
Emergency button is pressed accidentally
If the emergency stop button is accidentally pushed:
1. Verify that the situation is safe.
2. Pull the emergency out.
The emergency button is released and the charger is
reactivated.
After a few seconds the charger returns to normal op-
eration.