Astronergy CHSM6610M Installation Manual

Astronergy CHSM6610M Installation Manual

Crystalline silicon pv module
Hide thumbs Also See for CHSM6610M:

Advertisement

Crystalline Silicon PV
Module Installation
Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CHSM6610M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astronergy CHSM6610M

  • Page 1 Crystalline Silicon PV Module Installation Manual...
  • Page 2: Table Of Contents

    Catalogue Introduction ............................... 3 1.1 Purpose ................................3 1.2 Scope of liability ............................... 3 Regulations ................................. 3 Safety Precautions ............................. 3 3.1 General safety ..............................4 3.2 Operation safety measures ..........................5 Handling and unpacking ..........................6 4.1 Transport ................................6 4.2 Unpack ................................
  • Page 3: Introduction

    Chint Solar reserves the right to update this manual connection, and maintenance of following PV modules without prior notice. In case of any inconsistency manufactured by Chint Solar: between the description of different language versions CHSM6610M CHSM6610M(BL) CHSM6610M/HV of this manual, the Chinese version shall prevail. CHSM60M-HC...
  • Page 4: General Safety

     Chint Solar’s modules are designed to meet the  When installing or operating PV modules on rainy requirements of IEC61215 and IEC61730, and they days or dewy mornings, take appropriate protective have been qualified for Application Class A measures to prevent moisture from penetrating the (equivalent to Safety Class II requirements).
  • Page 5: Operation Safety Measures

     It is forbidden to disassemble and move any part of apply excessive load or distorted PV modules. the PV module; if the connector of the PV module  Do not install or carry PV modules by one person. is wet, do not perform any actions to avoid the risk It is forbidden to pick up, drag, or move PV of electric shock.
  • Page 6: Handling And Unpacking

    10cm. do not damage the surrounding PV modules or their support structures.  The connector must be fully mated when wiring. If  When cleaning PV modules, you must follow the the cable is too long, it is recommended to fix the cable to the rack system with a UV-resistant nylon cleaning requirements of PV modules.
  • Page 7: Unpack

     It is necessary to ensure the safety when unloading other side of the frame. Two people in turn move and PV modules, especially when hoisting roof take out the PV modules. The whole handling process projects. It is forbidden to use lifting straps directly needs to be handled gently to avoid any collision with on the pallet for hoisting.
  • Page 8: Mechanical Installation

    If the customer requires PV modules to be humidity environments, humid salt-mist distinguished by color, the outer packaging box shall environments (C3+areas specified in ISO 9223), be marked accordingly, and the PV modules shall be marine and floating environments and farms, the marked to prevent confusion when they are taken out purchaser or user needs to inform Chint Solar in of the packaging box and stacked up.
  • Page 9: Mounting Guide

    performance of the PV module. 5.3.1 Bolted mounting PV modules connected in series should be installed in All modules must be securely fastened with at least 4 the same orientation and angle. Different orientations bolts (As shown in Fig. 2, Fig. 3, Fig. 4 , Fig. 5 and and angles may result in different amounts of solar Fig.
  • Page 10: Clamped Mounting

    9~12Nm for M6 bolts and 17~23Nm for M8 bolts. Due to the possible difference of bolt material, the specific torque value is subject to the information confirmed by the bolt supplier. 5.3.2 Clamped mounting Fig 6. 400mm-pitched mounting hole, bolted mounting for Photovoltaic modules can be installed across the single axis tracker support frame (Fig.
  • Page 11 loads. mm. For module of 182mm-wafer, the size of mid and fringe clamp must meet a ≥ 60 mm. The  Each aluminum clamp is equipped with an M8 bolt, tightening torque is suggested to be 17~23Nm for a flat washer, a spring washer and an M8 nut. The Class 8.8 screw and bolts.
  • Page 12 Fig 2 & Fig 3 dimension Fig 5 Fig 8 Fig 9 Fig 6 L*W*H (mm) & Fig 4 +5400/-2400Pa +2400/-2400Pa 1648*990*35 +5400Pa Installation scope Installation scope CHSM6610M 1648*990*40 -2400Pa CHSM6610M/HV 198~408mm 50~200mm CHSM6610P +5400/-2400Pa +2400/-2400Pa CHSM6610P/HV 1650*992*35 +5400Pa Installation scope Installation scope...
  • Page 13 CHSM60M/LV-HC +5400/-2400Pa +2400/-2400Pa +5400Pa CHSM60M(BLH)-HC Installation scope Installation scope 1692*1002*35 -2400Pa 350±50mm 50~200mm +5400/-2400Pa +1800/-1800Pa 1755*1038*35 +5400Pa Installation scope Installation scope -2400Pa 1765*1048*35 400±50mm 200±50mm...
  • Page 14 Table 1 (continue) Installation method Dimensions Module type Fig 2 & Fig L*W*H (mm) Fig 5 Fig 8 Fig 9 Fig 6 3 & Fig 4 +5400/-2400Pa +1800/-1800Pa +5400Pa 1755*1038*30 Installation scope Installation scope -2400Pa 350±50mm 200±50mm CHSM60M-HC +5400/-2400Pa CHSM60M(BL)-HC 1755*1038*30 +5400Pa Installation scope...
  • Page 15: Electrical Installation

    CHSM72M(BL)-HC +5400/-2400Pa +2400Pa 2000*992*40 +5400Pa +5400Pa CHSM72M(BLH)-HC Installation scope -2400Pa 2000*992*35 -2400Pa -2400Pa 315~505mm +Bumper +5400/-2400Pa +2400Pa 2018*1002*40 +5400Pa +2400Pa CHSM72M-HC Installation scope -2400Pa 2018*1002*35 -2400Pa -2400Pa CHSM72P-HC 350±50mm +Bumper CHSM72M/LV-HC +5400/-2400Pa +2400Pa CHSM72M(BL)-HC 2108*1048*35 +5400Pa +2400Pa Installation scope -2400Pa CHSM72M(BLH)-HC 2094*1038*35 -2400Pa...
  • Page 16: Electrical Connection

    specification of the inverter. The total voltage equipment, current carrying capacity of wires and generated by PV modules in series should not be fuse and parameters associated with the output higher than the maximum voltage allowed by the power modules, corresponding system.
  • Page 17  If one PV module string (or PV array) is connected PV module is not connected correctly, the bypass diode may be damaged. Fig. 14 shows how the PV to another with opposite polarity, irreversible modules are connected in series and parallel. PV damage can be caused to the PV module product.
  • Page 18: Grounding

    unplug the connectors when the PV module is in live state. When it is necessary to remove the connectors, ensure that the PV module is not in working condition and that professional unlocking tools and safety measures are used. Direct dragging and pulling is forbidden.
  • Page 19: Maintenance

     Use UL-467 certified bonding and grounding PV modules without authorization. When conducting devices, including Burndy (formerly Wiley inspection or maintenance in term of the electrical and Electronics) Washer Electrical Equipment Bonding mechanical performance, it is recommended that (WEEB) and similar devices, such as barbed qualified professionals perform the work to avoid washers, that meet the requirements of UL-467 and electric shock or personal injury.
  • Page 20 dumps, hazardous substances can leak into the retailer is legally obligated to take back your old groundwater and get into the food chain, damaging appliance for disposals at least free of charge. your health and well-being. For more details on cleaning and maintenance, please refer to the PV Module Cleaning Manual.
  • Page 21: Modified Version And Date

    Modified version and date · Rev 1.0, released in June 2018. · Rev 1.1, released in July 2020. · Rev 1.2, released in October 2021. · Rev 1.3, released in Apr 2022. Chint New Energy Technology Co., Ltd. Add: No. 1 Jisheng Road, Jianshan New Zone, Haining Zhejiang, 314415 P. R. China.
  • Page 22 Annex1:The electric data Module family A: Poly c-Si cell type Type Name or Model CHSM6612P-xxx No............: (poly 72cells) CHSM6612P/HV-xxx (poly 72cells) CHSM6612P (BL)-xxx (poly 72cells) Maximμm System 1500 1000 Voltage [VDC] Rated Maximμm 310, 315, 320, 340, 345, 350, 355,360, 310, 315, 320, 325, 340, 345, 350, 355,360, Power [W] ..........
  • Page 23 Rated Short Circuit 9.68, 9.75, 9.83, 9.79, 9.68, 9.75, 9.83, 9.79, 8.95, 9.18, 9.45, 8.95, 9.18, 9.45, Current [A]..........: 9.86,9.81,9.99,10.13, 9.86,9.81,9.99,10.13, 9.52, 9.59 9.52, 9.59 10.22 10.22 Rated Open Circuit 38.94, 39.18, 38.94, 39.18, 39.42,39.51, Voltage [V]..........: 39.42,39.51, 37.72, 37.87, 38.00, 38.45, 37.72, 37.87, 38.00, 39.64,39.56,39.82, 40.04,...
  • Page 24 Cells per bypass diode Serial/parallel connection of cells CHSM6610M-xxx (mono 60 cells) CHSM6610M/HV-xxx Type Name or Model No............(mono 60 cells) CHSM6610M (BL)-xxx (mono 60 cells) Maximμm System 1500 1000 Voltage [VDC] Rated Maximμm 300, 305, 310, 275, 280, 285, 290,...
  • Page 25 Min- creepage 10.4 10.4 distance mm ........: Nμmber of solar cells Cells per bypass diode Serial/parallel connection of cells Module family C: ½ cut Poly c-Si cell type Type Name or Model No............: CHSM72P-HC-xxx CHSM72P/LV-HC-xxx ( poly 144 cells) (poly 144 cells) Maximμm System 1500...
  • Page 26 Serial/parallel connection of cells CHSM60P-HC-xxx CHSM60P/LV-HC-xxx Type Name or Model No............(poly 120 cells) (poly 120 cells) Maximμm System 1500 1000 Voltage [VDC] 300,305,310,315,320, 300,305,310,315,320, Rated Maximμm 260, 265, 270, 275, 280, 260, 265, 270, 275, 325,330,335,340,345, 325,330,335,340,345, Power [W] ..........: 285, 290, 295 280, 285, 290, 295 350,355,360,365...
  • Page 27 Rated Maximμm 360, 365, 370, 375, 330, 360, 365, 370, 375, 380, Power [W] ..........: 380, 385, 390, 395, 335, 330, 335, *520, 525, 530, 385, 390, 395, 400, 405, *520, 525, 530, 400, 405, 410, 415, 340, 340, 345, 535, 540, 545, 410, 415, 420, 425, 430, 535, 540, 545,...
  • Page 28 Maximμm System 1500 1000 Voltage [VDC] Rated Maximμm 300, 305, 310, Power [W] ..........: 315,320,325, 300, 275, 275, 330, 335, 340, 345,350, 305,310,315,320,325, 280, 280, *590,595,600, *590,595,600, 355, 285, 330,335, 340, 345,350, 285, 605,610 605,610 290, 355, 360, 365, 370, 290, 360, 365, 370, 375, 380,385, 390, 395...
  • Page 29 - Power range of model type CHSM60M-HC-xxx / CHSM60M/LV-HC-xxx from 590W to 610W is with cell dimension 210mmx105mm. Type Name or Model CHSM66M-HC-xxx No............: (mono 132 cells) Maximμm System 1500 1500 Voltage [VDC] Rated Maximμm 480, 485, 490, 495, 395, 400, 405, 410, 415 645,650,655,660,665,670,675 Power [W] ...........
  • Page 30 Fire rating ........... : Class C Class C Pollution degree ........: Dimensions (l x w x h) 2073x1133x35 2096x1038x35(30) 2384x1303 x35 [mm] ........... : 2094x1134x35 Module area [m²] ......... : 2.18 2.35/2.37 3.11 Min- creepage 10.4 10.4 distance mm ........: Nμmber of solar cells Cells per bypass diode...
  • Page 31 *Remark: Power range of model type CHSM54M-HC-xxx / CHSM54M/LV-HC-xxx from 390W to 415W is with cell dimension 182mmx91mm. Power range of model type CHSM60M-HC-xxx / CHSM60M/LV-HC-xxx from 435W to 465W is with cell dimension 182mmx91mm. CHSM55M-HC-xxx CHSM55M/LV-HC-xxx CHSM50M-HC-xxx CHSM50M/LV-HC-xxx Type Name or Model No.
  • Page 32 9.41, 10.17,10.24,10.31, 9.52, 9.57 10.10,10.17,10.24, 9.46, 10.38,10.45,10.52, 10.31,10.38,10.45, 9.52, 11.03,11.10,11.16, 10.52,11.03,11.10, 9.57 11.24, 11.30, 11.37, 11.16,11.24, 11.30, 11.44 11.37, 11.44 Rated Open Circuit 47.13, 47.44, 47.64, 47.13, 47.44, 47.64, Voltage [V] .......... : 47.89, 48.18, 48.47, 47.89, 48.18, 48.47, 45.30, 48.70, 48.98, 49.25, 48.70, 48.98, 49.25, 45.61,...
  • Page 33 370,375,380 370,375,380 Rated Short Circuit 9.64, 9.73, 9.82, 9.90, 9.64, 9.73, 9.82, 9.90, Current [A] .......... : 9.28, 9.98,10.06,10.14,10.22, 9.28, 9.98,10.06,10.14,10.22, 9.36, 9.36, 13.38,13.48, 13.38,13.48, 9.43, 10.30,10.38,10.46,11.15, 9.43, 10.30,10.38,10.46,11.15,1 9.51, 13.59.13.71 9.51, 13.59.13.71 1.21,11.29, 11.35, 9.59 9.59 11.21,11.29, 11.35,11.42, 11.49 11.42, 11.49 Rated Open Circuit 39.75, 39.84, 40.11,...
  • Page 34 Maximμm System 1500 1000 1500 1000 Voltage [VDC] Rated Maximμm 390,395,400,405 585,590,595,600,605 Power [W] ........... : Rated Short Circuit 13.40,13.52,13.65,13.76 13.68,13.77,13.85,13.93,14.01 Current [A] .......... : Rated Open Circuit 36.60,36.80,37.00,37.20 53.84,54.04,54.24,54.44,54.64 Voltage [V] .......... : Tolerance of Rating 3 / 5 / 3 3 / 5 / 3 Pmax / Isc / Voc [%] ......
  • Page 35 Pollution degree ........: Dimensions (l x w x h) 2384x1303 x35 2172 x 1303 x 35 [mm] ........... : Module area [m²] ......... : 3.11 2.83 Min- creepage 10.4 10.4 distance mm ........: Nμmber of solar cells Cells per bypass diode Serial/parallel connection of cells...
  • Page 36 No............: (mono 108 cells) (mono 108 cells) (mono 120 cells) (mono 120 cells) Maximμm System 1500V 1000V 1500V 1000V Voltage [VDC] Rated Maximμm 405,410,415,420,425 450,455,460,465,470 Power [W] ........... : Rated Short Circuit 13.41,13.58,13.76,13.87,13.98 13.60,13.71,13.81,13.91,14.01 Current [A] .......... : Rated Open Circuit 37.76,37.78,37.80,38.00,38.20 41.35,41.55,41.75,41.95,42.15...
  • Page 37 Pollution degree ....... : Dimensions (l x w x 2278x1134x35 1722x1134 x30 h) [mm] ..........: Module area [m²]....... : 2.58 1.95 Min- creepage 10.4 10.4 distance mm ........: Nμmber of solar cells Cells per bypass diode Serial/parallel connection of cells CHSM60N(BLH)-HC-xxx CHSM60N(BL)-HC-xxx Type Name or Model...
  • Page 38 Pmp ~ Ima are measured under STC (irradiance = 1000 mW/cm2, AM = 1.5, and cell temperature = 25°C)

Table of Contents