BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY
- Check the pack and make sure you have all the parts listed.
- When you are ready to start, make sure you have the right tools at hand (not supplied)
including a Phillips screwdriver, Stanley knife, wood saw, step ladder and drill with 2mm
bit.
- Ensure there is plenty of space and a clean dry area for assembly.
TIMBER
As with all natural materials, timber can be a ected during various weather conditions.
For the duration of heavy or extended periods of rain, swelling of the wood panels may
occur. Warping of the wood may also occur during excessive dry spells due to an interior
moisture loss. Unfortunately, these processes cannot be avoided but can be helped. It is
suggested that the outdoor building is sprayed with water during extended periods of
warm sunshine and sheltered as much as possible during rain or snow.
Our buildings are pre treated with a water based treatment**; this only helps to protect
the product during transit and for upto 3 months against mould. To validate your
guarantee and ensure longevity of the product, it is ESSENTIAL the building is treated
with a wood preserver within the rst three months of assembly and thereafter in
accordance with the manufactures recommendations. Care must be taken to ensure
the product is placed on a suitable base.

BUILDING A BASE

When thinking about where the building and base is going to be constructed:
Ensure that there will be access to all sides for maintenance work and annual
treatment.
Ensure the base is level and is built on rm ground, to prevent distortion. Refer to
diagrams for the base dimensions, The base should be slightly smaller than the external
measurement of the building, i.e. The cladding should overlap the base, creating a run
o for water. It is also recommended that the oor be at least 25mm above the
surrounding ground level to avoid ooding.

TYPES OF BASE

- Concrete 75mm laid on top of 75mm hard-core.
- Slabs laid on 50mm of sharp sand.
Whilst all products manufactured are made to the highest standards of Safety and in
the case of childrens products independently tested to EN71 level, we cannot accept
responsibility for your safety whilst erecting or using this product.
Refer to the instructions pages for you speci c product code
Please retain product label and instructions for future reference
x2
All building's should be
erected by two adults
For ease of assembly, you
MUST pilot drill all screw
holes and ensure all screw
heads are countersunk.
2mm Drill bit

Pressure Treated Timber

Pressure treating is a chemical process which helps to protect wood against adverse weather which could
lead to rot or insect damage.
The most common chemicals used to pressure treat wood are Alkaline Copper Quaternary (ACQ),
Copper Azole (CA), and Micronized Copper Quaternary (MCQ).
Safety: Always wear gloves, eye protection and a dust mask when handling wood. Due to chemicals in
pressure treated wood, never burn its sawdust or scraps; instead dispose in a land ll.
For assistance please contact customer care on: 01636 880514
Mercia Garden Products Limited,
Sutton On Trent,
Newark,
Nottinghamshire,
NG23 6QN
www.merciagardenproducts.co.uk
Winter = High Moisture = Expansion
Summer = Low Moisture = Contraction
CAUTION
Every e ort has been made during the
manufacturing process to eliminate the
prospect of splinters on rough surfaces of the
timber. You are strongly advised to wear gloves
when working with or handling rough sawn
timber.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 01PTOSBRA0806SDFW-V1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mercia Garden Products 01PTOSBRA0806SDFW-V1

  • Page 1 For assistance please contact customer care on: 01636 880514 - Concrete 75mm laid on top of 75mm hard-core. - Slabs laid on 50mm of sharp sand. Mercia Garden Products Limited, Sutton On Trent, Whilst all products manufactured are made to the highest standards of Safety and in...
  • Page 2 01PTOSBRA0806SDFW-V1 Please retain product label and instructions for future reference Overall Dimensions: Nail Bag Felt Tacks x 100 Length = 1905mm 20mm Screw x 14 Width = 2414mm Height = 2216mm 30mm Black Screw x 2 Base Dimensions: 30mm Screw x 58...
  • Page 3 Please retain product label and instructions for future reference Step 1 Step 3 Fix the corners with 50mm Place the oor on a rm and level base, screws as shown in diagram. ensure the base has suitable drainage free from areas where standing water can collect. 9x50mm Screws See the front page for base requirments.
  • Page 4 Please retain product label and instructions for future reference Step 5 Step 7 Fix two eaves frames to each roof sheet using 3x30mm screws per eave. Cut the felt into three equal strips of 2490mm and lay onto roof as shown in Fix the roof sheets to the roof ensuring diagram ensuring there is overhang they come together at the top using...
  • Page 5 Please retain product label and instructions for future reference Step 10 Step 8 Fit the Cover Trims to the front Use 4x30mm screws to x and back of the building as each beading strip onto the shown in the illustration using door panel.
  • Page 6 Please retain product label and instructions for future reference Step 11 Fix the pad bolt with 6x30mm screws to the horizontal brace on the door. Then x the pad bolt retainer to the door panel framing using 4x30mm screws. AFTER TREATMENT: Fix the turn buttons using score around protective 1x30mm black screw per turn...

Table of Contents