Thermal Monitor; Drive Self Test (Dst) - Seagate ST6000NM0075 Product Manual

Hide thumbs Also See for ST6000NM0075:
Table of Contents

Advertisement

5.2.4

Thermal monitor

Seagate Exos 7E8 SAS drives implement a temperature warning system which:
1.
Signals the host if the temperature exceeds a value which would threaten the drive.
2.
Saves a S.M.A.R.T. data frame on the drive which exceeds the threatening temperature value.
A temperature sensor monitors the drive temperature and issues a warning over the interface when the temperature exceeds a set threshold. The
temperature is measured at power-up and then at ten-minute intervals after power-up.
The thermal monitor system generates a warning code of 01-0B01 when the temperature exceeds the specified limit in compliance with the SCSI
standard.
This feature is controlled by the Enable Warning (EWasc) bit, and the reporting mechanism is controlled by the Method of Reporting Informational
Exceptions field (MRIE) on the Informational Exceptions Control (IEC) mode page (1Ch).
5.2.5

Drive Self Test (DST)

Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a failed unit. DST validates the
functionality of the drive at a system level.
There are two test coverage options implemented in DST:
1.
Extended test
2.
Short test
The most thorough option is the extended test that performs various tests on the drive and scans every logical block address (LBA) of the drive. The
short test is time-restricted and limited in length—it does not scan the entire media surface, but does some fundamental tests and scans portions
of the media.
If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test, remove it from service and return it to
Seagate for service.
5.2.5.1
DST failure definition
The drive will present a "diagnostic failed" condition through the self-tests results value of the diagnostic log page if a functional failure is
encountered during DST. The channel and servo parameters are not modified to test the drive more stringently, and the number of retries are not
reduced. All retries and recovery processes are enabled during the test. If data is recoverable, no failure condition will be reported regardless of the
number of retries required to recover the data.
The following conditions are considered DST failure conditions:
• Seek error after retries are exhausted
• Track-follow error after retries are exhausted
• Read error after retries are exhausted
• Write error after retries are exhausted
Recovered errors will not be reported as diagnostic failures.
Seagate Exos 7E8 SAS Product Manual, Rev.A
21

Advertisement

Table of Contents
loading

Table of Contents