Electronic push button cabinet lock

Advertisement

KEYPAD version
Pearl
– installation instructions
Electronic push button cabinet lock
Programming Single Use Timeout ON / Single Use Timeout OFF
Warning: Manual Lock - Single Use
Timeout ON is a feature to prevent
users from occupying a shared use
locker or cabinet for a prolonged
period of time. Turning this feature
on will disable the user code after a
programmable amount of time. After
this time elapses, Pearl can only be
opened with the supervisor code.
To change the Pearl to Single Use
Timeout ON or OFF, follow the steps on
page 5 to enter programming mode.
There is a 10 second programming time
limit between each step. If Pearl times
out or an error is made, programming
will end and you will need to enter
programming mode again.
Programming Security Timeout ON / Security Timeout OFF
Warning: Security Timeout ON will
disable the Pearl from use for 5 minutes
when 5 invalid attempts to unlock Pearl
occur. During this time, Pearl will not
unlock with either the valid user or
supervisor code.
To change the Pearl to Security Timeout
ON or OFF, follow the steps on page 5
to enter programming mode.
There is a 10 second programming time
limit between each step. If Pearl times
out or error is made, programming
will end and you will need to enter
programming mode again.
8
1. Place Pearl into programming
mode (see page 5).
3. If successful, the green indicator
light will illuminate for 1 second.
Continue programming or press 9 and
then
1. Place Pearl into programming
mode see page 5).
2. If successful, the green indicator
light will illuminate for 1 second.
Continue programming or press 9 and
then
Pearl — Installation instructions: KEYPAD version
a. To set Timeout ON, type
2XX and then press
(enter).
(XX represents a time
period from 04 to 48 in
whole hours.)
OR
b. To turn Timeout OFF, type
20 and then press
(enter).
(enter) to exit programming.
a. To turn Security Timeout
ON, type 11 and then
press
(enter).
OR
b. To turn Security Timeout
OFF, type 10 and then
press
(enter).
(enter) to exit programming.