5-channel ac load current measurement module (11 pages)
Summary of Contents for ICP DAS USA iSN-713-MRTU
Page 1
Quick Start v1.0, March 2022 Packing List In addition to this guide, the package includes the following items: iSN-713-MRTU Resources How to search for drivers, manuals and spec information on ICP DAS website. Technical Support For Mobile Web service@icpdas.com...
Page 2
RS-232 to RS-485 Converter: tM-7520U (optional) Exterior power supply device: MDR-20-24 (optional) Wiring Connect both the iSN-713-MRTU module and the Host PC via the tM-7520U. Connect the VCC pin to positive terminal on a 10 ~ 30 V DC power...
Page 3
Factory Default Settings The following is an overview of the factory default settings: Item Default Device ID Baud Rate 9600 bps Parity: NONE Data Format Data length: 8 (Fixed) Stop Bits: 1 Protocol Modbus RTU Modbus Register Table (Based 0) RS-485 Communication parameters Holding Register (4xxxx) Register...
Page 4
Vibration Features Input Register (3xxxx) Register Points Description Axis Unit Attribute 30012 000B RMS value of acceleration 30013 000C Maximum value of acceleration 30014 000D Peak to Peak value of Acceleration 30015 000E Crest Factor value of Acceleration 0.01 CF 30016 000F RMS value of Velocity...