How to set ACK input (MC-3020D)
Use the connectors J3 to J6 on the MC-DIN Board (24P0116) to set the ACK input for
ACK1 to ACK8 as shown below.
• Input circuit for voltage input
DC voltage input
(21.6V to 31.2V)
• Input circuit for contact input
Use NH connector
and AWG24 wire.
Contact input
Note 1: The input must not exceed the range of the input voltage, to prevent malfunc-
tion.
-Setting for voltage input: 21.6 V to 31.2 V
-Setting for contact input: Voltage cannot be input (contact signal only).
Note 2: For analog input, see page 2-23
Connector J5
In/Out
Description
In
Analog 3 input
-
Analog 3 GND
-
Analog 3 input, power current/
voltage setting jumper 1
-
Analog 3 input, power current/
voltage setting jumper 1
470Ω/ 0.5W
DC12V_OUT
+
DIGI_IN1
DIGI_RTN1
-
GND(DC12V)
12V
470Ω/ 0.5W
DC12V_OUT
DIGI_IN1
DIGI_RTN1
GND(DC12V)
voltage
TTYCS(LA)-1
Pin #3-#4:
open
12V
2.2kΩ / 1W
GND
Photocoupler circuit
GND
2.2kΩ / 1W
GND
Photocoupler circuit
GND
2. WIRING
Power
Power
current
Pin #3-#4:
short
5V
Register
to Processor unit
circuit
5V
Register
to Processor unit
circuit
2-25