Furuno ECDIS FMD-3200 Installation Manual page 32

Electronic chart display and information system
Hide thumbs Also See for ECDIS FMD-3200:
Table of Contents

Advertisement

2. WIRING
How to set contact input/output
The connector J11 can be used for the connection of contact input or voltage input.
Refer to the figures shown below to make the wiring which complies with the input
specification.
Note: The input must not exceed the range of the input voltage, to prevent malfunc-
tion.
-Setting for voltage input: 21.6V to 31.2V
-Setting for contact input: Voltage cannot be input (contact signal only).
• (Setting for contact input)
Use NH connector
and AWG24 wire.
Contact input
• (Setting for voltage input)
DC voltage input
(21.6V to 31.2V)
Pin #
Signal name
1
SYS_FAIL-A
2
SYS_FAIL-B
3
PWR_FAIL-A
4
PWR_FAIL-B
5
NC1-A
6
NC1-B
7
NC2-A
8
NC2-B
9
NO1-A
10
NO1-B
11
NO2-A
12
NO2-B
13
DC12V_OUT
14
DIGI_IN1
15
DIGI_RTN1
16
GND (DC12V)
17
GND
Note: NC1/2 and NO1/2 are output with a fixed value.
2-12
12V
470Ω/ 0.5W
DC12V_OUT
DIGI_INx
DIGI_RTNx
GND(DC12V)
470Ω/ 0.5W
DC12V_OUT
+
DIGI_INx
DIGI_RTNx
-
GND(DC12V)
Connector J11
In/Out
Description
Out
System fail output (NC) TTYCS(LA)-10
Out
System fail output (NC)
Out
Power fail output (NC)
Out
Power fail output (NC)
Out
Alarm output (NC1)
Out
Alarm output (NC1)
Out
Alarm output (NC2)
Out
Alarm output (NC2)
Out
Alarm output (NO1)
Out
Alarm output (NO1)
Out
Alarm output (NO2)
Out
Alarm output (NO2)
Out
ACK input
In
ACK input
Out
ACK input
In
ACK input
-
GND
2.2kΩ / 1W
GND
Photocoupler circuit
GND
12V
2.2kΩ / 1W
GND
Photocoupler circuit
GND
Contact input
#13-#14: short
TTYCS(LA)-10
NO connection
5V
Register
to MC-DIN
circuit
5V
Register
to MC-DIN
circuit
Voltage input
TTYCS(LA)-10
No connection
TTYCS(LA)-10
No connection

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecdis fmd-3300Ecdis fmd-3200-bb

Table of Contents