APPENDIX 4 ALERT LIST
Alert No.
ALF ID
ALR ID
30001,27
090
30001,28
070
30001,29
071
30001,30
072
30001,31
400
30001,32
401
30002,3
006
30002,4
019
30002,5
007
30002,6
008
AP-38
Alert Name, Meaning and Remedy
Name: Processor Unit CPU board Core Power Error
Meaning: CPU board core voltage error has occurred.
Remedy: Turn off the processor unit. Wait several minutes then turn on
the power. If the message appears, contact a FURUNO agent or dealer
to request service.
Name: RCU 1 COM Timeout
Meaning: Communication error with No. 1 control unit has occurred for 40
seconds or more.
Remedy: Check the connection with the control unit.
Name: RCU 2 COM Timeout
Meaning: Communication error with No. 2 control unit has occurred for 40
seconds or more.
Remedy: Check the connection with the control unit.
Name: RCU 3 COM Timeout
Meaning: Communication error with No. 3 control unit has occurred for 40
seconds or more.
Remedy: Check the connection with the control unit.
Name: Network Printer Not Available
Meaning: The network printer cannot be detected. There may be a con-
nection error or an error (out of paper, jam, out of ink, etc.) on the printer
side.
Remedy: Make sure the printer is connected to the network. Make sure
that no errors (out of paper, jam, out of ink, etc.) have occurred on the
printer side.
Name: Local Printer Not Available
Meaning: The local printer cannot be detected. There may be a connec-
tion error or an error (out of paper, jam, out of ink, etc.) on the printer side.
Remedy: Make sure the printer is connected to the network. Make sure
that no errors (out of paper, jam, out of ink, etc.) have occurred on the
printer side.
Name: Main Monitor High Temperature Inside Monitor
Meaning: The internal temperature of the display (main monitor) connect-
ed to COM1 is rising.
Remedy: If this occurs frequently, contact a FURUNO agent or dealer and
report the frequency of occurrence.
Name: Sub Monitor High Temperature Inside Monitor
Meaning: The internal temperature of the display (sub monitor) connect-
ed to COM2 is rising.
Remedy: If this occurs frequently, contact a FURUNO agent or dealer and
report the frequency of occurrence.
Name: Main Monitor Fan1 No Rotation
Meaning: The No. 1 fan of the main monitor (FURUNO make) connected
to COM1 has stopped rotating.
Remedy: If this occurs frequently, contact a FURUNO agent or dealer
about replacement of the fan.
Name: Main Monitor Fan2 No Rotation
Meaning: The No. 2 fan of the main monitor (FURUNO make) connected
to COM1 has stopped rotating.
Remedy: If this occurs frequently, contact a FURUNO agent or dealer
about replacement of the fan.