7.2 DESCRIPTION

7.2.1 SPECIFICATION ABOUT THE THERMAL PROTECTION

* The change of HI / LO have hysterisis curve below.
Reading value of the season and FAN drive.
T4
(Outside air 60°C)
T3
(Outside air 38.5°C)
T2
(Outside air 35.5°C)
T1
(Outside air 33°C)
T0
(Outside air 30°C)
FAN : STOP
Assign
76pin
This model controls the FAN drive by MAIN u-com pin 149 (FAN ON / OFF) pin 17 (Cange of FAN control voltage) ,
not by the traditional PWM.
Set State and FAN Drive
Set State and FAN Drive
POWER
PSW1
ON
ON
ON
ON
OFF
[ Outline Circuit ]
17
UCOM
149
5
6
FAN : LO
FAN : HIGH
FAN : HIGH
AD value
(Thermister)
8 bit
TEMP2
T4 setting
105
T3 setting
131
T2 setting
139
T1 setting
141
T0 setting
149
Assign
FAN : HIGH
IC5206 149pin
H
FAN_CONT
IC5206 17pin
H
FAN_CONT_POW
State
Control
ON
According to the reading value of above table sensor. ON (HIGH/LO/STOP)
DT_REC According to the reading value of above table sensor. ON (HIGH/LO/STOP)
STB
FAN CONT
H
Vo = 9.57V
:
L
:
Vo = 7.10V
6
7
FAN : LO
FAN : STOP
FAN : STOP
AD value
Aime
(Thermister)
(Outside air of
(Sensor position)
10 bit
420
60°C
524
46°C
556
41°C
564
40°C
596
35.5°C
FAN : LO
STOP
H
L
L
-
Vo
FAN_vcc
REG
Vref = 2.65V
H : On
L : Off
PDP-436SXE
7
8
FAN : LO
FAN : HIGH
SD
Aime
Unit)
55°C
38.5°C
38.5°C
33°C
30°C