Linksys NSS4000 Series Administrator's Manual page 140

Business series network storage system
Hide thumbs Also See for NSS4000 Series:
Table of Contents

Advertisement

• UPS: When any of the following occurs: 1) the UPS goes online, 2) the UPS goes on battery,
3) the battery is low, 4) the NSS establishes contact with the UPS, 5) the NSS loses contact
with the UPS (after communication was successfully established), 6) the UPS is about to shut
down the system, 7) the UPS battery needs to be replaced, 8) the NSS cannot talk to the UPS.
6. Click Add.
The management station appears in the Existing SNMP Trap Sinks list.
7. Repeat steps 4 through 6 for each SNMP server address to which you want to send alerts.
8. To send a test alert for each of the selected conditions to all configured trap sinks, click Test All.
To delete an existing SNMP Trap Sink, click Delete.
Chapter 7: Admin
Configuring SNMP Alerts
Network Storage System (NSS) Administrator Guide
Chapter
7
138

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nss6000 series

Table of Contents