Bosch rexroth RegisterControl ATEX MLC 14VRS Operating Instructions Manual page 28

Table of Contents

Advertisement

24/39
Mounting, demounting and electric installation
The sensor optics PY-MSS01.3-O1 has the following dimensions:
Fig. 10-5: Sensor optic dimensions PY-MSS01.3-O1
Mount the sensor optics to an area that is electrically conducting
and connected to a grounding conductor!
The metallic shrink sleeve of the OWG has to be grounded as well.
The background the spot is focusing on, has to be monochrome.
The OWG spiraled hose is available with lengths from 2 m to 6 m, in steps of
0.5.
The material web with the marks to be detected has to have with a fixedly de-
fined distance to the sensor optics that corresponds exactly to the distance of
the protective cap. The distance is 16.7 mm. The sensor optics has to be moun-
ted parallel to the material web.
The following figure shows the correct alignment of the optics to the web.
Please comply with these assembly instructions.
Bosch Rexroth AG R911341913_Edition 05