Download Print this page
ICP DAS USA I-7018 Quick Start Manual

ICP DAS USA I-7018 Quick Start Manual

Hide thumbs Also See for I-7018:

Advertisement

Quick Links

I-7018(R)(BL)(P), M-7018(R) Quick Start Guide
Warranty
All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date
of delivery to the original purchaser.
Warning
ICP DAS assumes no liability for damages resulting from the use of this product. ICP DAS reserves the right to change this
manual at any time without notification. The information furnished by ICP DAS is believed to be accurate and reliable.
However, no responsibility is assumed by ICP DAS for its use, or for any infringements of patents or other rights of third
parties resulting from its use.
Packing List
I-7018(R)(BL)(P) or M-7018(R)
 Internal I/O Structure < I-7018(BL)(P), M-7018 > 
Internal I/O Structure < I-7018R, M-7018R >
Wire Connections < I-7018(BL)(P) Channel 0 – 5, M-7018 , I-7018R, M-7018R >
Plastic Rail
Pin Assignments < I-7018(BL)(P) >
Pin Assignments
< I-7018R, M-7018, M-7018R >
CD
Quick Start Guide
Page 1

Advertisement

loading

Summary of Contents for ICP DAS USA I-7018

  • Page 1  Internal I/O Structure < I-7018(BL)(P), M-7018 >  Pin Assignments < I-7018(BL)(P) >  Pin Assignments < I-7018R, M-7018, M-7018R >  Internal I/O Structure < I-7018R, M-7018R >  Wire Connections < I-7018(BL)(P) Channel 0 – 5, M-7018 , I-7018R, M-7018R > Page 1...
  • Page 2  Wire Connections < I-7018(BL)(P) Channel 6 – 7 >  Modbus Table (M-7018, M-7018R only) Address Description Address Description 30001 ~ Analog input value of channel 0 to 7 40488 Modbus response delay time in ms, 30008 valid range: 0 ~ 30...
  • Page 3  Module test and configuration Step 1: INIT switch Operation Step 2: Install & Run DCON Utility 1. Please Install DCON Utility first You can find the software in the CD. CD path: <Driver>:\napdos\driver\dcon_utility\ Web link: http://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_utility/ 2. Run DCON utility 1.
  • Page 4 ICP DAS provide DCON Utility to configure I-7000 and M-7000 modules. Please download the last version from: http://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_utility/ Q3. How to measure the current? I-7018(R)(BL)(P) and M-7018(R) require optional external resistance (125Ω) for current measurement. Please refer wired connections diagram. And then select a suitable input range by DCON Utility.

This manual is also suitable for:

I-7018rI-7018blI-7018pM-7018M-7018r