4. TROUBLESHOOTING

(1) Check the following points before asking for repair.
Symptom
Water is not drawn normally.
1. Check the Filter Unit. Clean the Filter if it is clogged by stain and dirt (refer to Filter Unit Cleaning at page 6).
2. Check the Shower Head. Clean the Shower Head if it is clogged by dirt (refer to Shower Head Cleaning at
No hot water comes out from
1. Make sure the Main Switch Knob is at "On" position.
the outlet
2. Make sure the ELB Reset Lever is not slide down.
(no electric supply to the Unit)
3. Make sure to switch on the ON/OFF DP (double pole) Switch.
4. Make sure to switch on the Miniature Circuit Breaker (MCB)
No water flows out from the
1. Check the Water Volume Knob. Turn the Water Volume Knob clockwise if it is closed.
Shower Head at all.
2. Check the Main Water Valve. Turn "On" the Main Water Valve if it is closed (refer to HOW TO USE at page 5).
Water not hot enough.
1. Check the WATER FLOW RATE ADJUSTMENT as in page 5.
(2) If abnormalities as mentioned below are found during use, please do not use the Unit and contact your authorized dealer immediately.
1) Water leakage.
2) No Water Flow.
3) Water temperature cannot be controlled.
4) ELB lamp does not light up.
(3) Special skill is required for repairing. Never try to repair the Unit by yourself.

5. SPECIFICATIONS

Model No
Voltage
Power Consumption
Off (Inlet Water Temp.),
Power Selector
Lo (1170 W), Med (2330 W),
Min. Water Pressure
Max. Water Pressure
Dimension
Weight
Outlet System
page 6).
Push up the ELB Reset Lever to reset the ELB (refer to TEST OPERATION at page 11).
DH-3RL2
DH-4RL1
3500 W
4500 W
Off (Inlet Water Temp.),
Lo (1500 W), Med (3000 W),
& Hi (3500 W)
& Hi (4500 W)
9.8 kPa / 0.1 kgf/cm² / 1.42 psi
380 kPa / 3.87 kgf/cm² / 55 psi
380(H) mm x 190(W) mm x 93(D) mm
1.6 kg
1.9 kg
Single Point System (Open Outlet)
- 7 -
Points to be checked
DH-3RP2
220 V a.c. 50 Hz
3500 W
Off (Inlet Water Temp.),
Lo (1170 W), Med (2330 W),
& Hi (3500 W)
4.9 kPa / 0.05 kgf/cm² / 0.71 psi
2.7 kg
DH-4RP1
4500 W
Off (Inlet Water Temp.),
Lo (1500 W), Med (3000 W),
& Hi (4500 W)
2.9 kg

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Dh-3rp2Dh-4rl1Dh-4rp1