HOW TO INSTALL ELECTRIC HOME SHOWER

• Proper size of Flexible Cord and electric wiring must be installed to avoid smoke emission and fire hazards.
• Make sure to turn off the electric and water supply during installation process.
• The home shower must be permanently connected to the electric supply through the ON/OFF DP (double
pole) Switch having a contact separation of at least 3 mm in all poles incorporated in the fixed wiring. This
switch must be clearly identifiable but out of reach of a person using a fixed bath or shower.
The Unit must be earthed.
Improper grounding could cause electric shock.
• Never install Filter Body Assembly at the outlet, inlet water cannot be filtered and allows
foreign particles to enter the Unit. It will cause Heater Unit and Shower Head to clog up.
• Do not install, remove and reinstall the Unit by yourself.
Improper installation will cause leakage, electric shock or fire. Installation and wiring must be
done by competent personnel.
• Do not share the inlet and outlet pipe of the Home Shower Unit with other outlets.
The pressure may drop due to water being drawn off at other point. The shower temperature
may become very hot.
Flexible Cord must enter the Unit thru designated point only (do not make additional holes).

1. BEFORE INSTALLATION

(1) Make sure water flow pressure.
Min. water pressure
Max. water pressure
How to measure the water pressure as illustrated. Water should
flow out of the Hose 2.0 m above the Main Water Valve.
Note:
When removing the Unit from package, some water may be found inside.
This is normal as the Unit is tested during the manufacturing process.

2. HOW TO INSTALL

WARNING
Make sure to turn off the electric and water
supply during installation process.
1. Where to install the Unit.
• Be sure to install the Unit on the wall as illustrated
in Figure 1 (vertical position with the water fittings
pointing downward).
• Do not install the Unit away from wall surface as
shown in Figure 2.
• The Unit must be installed at 1.5 m ~ 1.7 m above
the floor.
WARNING
CAUTION
9.8 kPa / 0.1 kgf/cm² / 1.42 psi (DH-3RL2 & DH-4RL1)
4.9 kPa / 0.05 kgf/cm² / 0.71 psi (DH-3RP2 & DH-4RP1)
380 kPa / 3.87 kgf/cm² / 55 psi
Cold Water
Service Valve
For DH-3RP2 & DH-4RP1
- 8 -
Main Pipe
Tank
Rising Level
33 ft (10 m) maximum
recommended height between
bottom of cold water tank and
top of Home Shower Unit.
ELB
Lo
Med
Off
Hi
ELB Test
Power Selector
Off
On
* Maximum total length
Main Switch
OFF
of feeding pipe should
MAX
CLEANING
FILTER
be below 10 meter.
1.5 m ~
* The feeding pipe
1.7 m
should be 1/2 inch.
For DH-3RL2 & DH-4RL1
ELB
Lo
Med
Off
Hi
ELB Test
Power Selector
Off
On
Main Switch
Filter Body
OFF
MAX
FILTER
Assembly
CLEANING
Water Outlet
Water Inlet
2.0 m
ELB
Figure 1
Lo
Med
Off
Hi
ELB Test
Power Selector
Off
On
Main Switch
OFF
MAX
CLEANING
FILTER
1.5 m ~
1.7 m
Figure 2