2. How to remove the Front Plate
① Make sure the Main Switch Knob and the Power
Selector Knob are at "Off" condition.
② Remove the screw at the bottom of the Unit.
③ Lift up the Main Switch Knob and the Power Selector
Knob to make it free (Main Switch Knob and Power
Selector Knob are attached to Rotary Shaft inside the
Unit). Make sure the Main Switch Knob and the Power
Selector Knob are not detached from the Front Plate.
④ Remove the Front Plate by lifting up the bottom side
and then unhook the top side.
3. How to fix Electric Home Shower.
① The distance of the Unit should be more than 250 mm
from the right and left side of the wall.
118 mm
Wall
Screw
Screw
250 mm
minimum
142 mm
186 mm
④ Lead the Flexible Cord to the set thru Portion 1 or 2 as shown below for electric wiring process.
Portion 1
Portion 2
⑤ • Mount the Unit on the wall with 4 screws.
• Drive each Screw into the two upper Wall Plugs through
the screw holes on the Back Plate.
• After tighten up the two upper Screws, tighten up the
remaining two Screws.
4. Electric wiring
WARNING
WARNING
① Lead the Flexible Cord connected to ELB terminal inside the Unit:
2.5 mm², 3 core Flexible Cord.
ELB Test
ELB Reset
Push Up
Wall
250 mm
minimum
Portion 1
Portion 2
CAUTION
Back Plate
Screw
Wall
Wall Plug
Proper size of Flexible Cord and electric wiring must be installed to avoid
smoke emission and fire hazards.
The Home Shower must be permanently connected to the electric supply
through the ON/OFF DP (double pole) Switch having a contact separation
of at least 3 mm in all poles incorporated in the fixed wiring. This switch
must be clearly identifiable but out of reach of a person using a fixed bath
or shower.
- 9 -
Note:
Main Switch Knob and Power Selector Knob are attached to Front Plate.
Do not remove Main Switch Knob and Power Selector Knob from Front Plate.
ELB
Lo
Med
Power
Selector Knob
Off
Hi
Power Selector
ELB
Off
On
Main
Lo
Med
Switch Knob
Off
Hi
Power Selector
Main Switch
Off
On
Main Switch Knob
and Power Selector Knob
Main Switch
DH-3RL2
Screw
② Make 4 holes at the wall by means of a drill.
③ Drive a Wall Plug into the hole.
25 mm
Ø6 mm
View from inside of the Unit
Flexible Cord must enter the Unit thru
designated point only (do not make
additional holes).
⑥ Please ensure the set fixed tightly on the wall by shaking
it left and right.
Note: The Back Plate must be mounted with 4 Screws.
Wall
Wall Plug
Earth
ON / OFF DP
(double pole) Switch
Miniature Circuit
Breaker (MCB)
Bath Room
Lift up
Front Plate
Wall Plug
Back Plate
Flexible Cord 2.5 mm², 3 core
WARNING
L(+)
(-)N
MUST BE TIGHTEN