Electrical Box

3. Electrical Box
Warning
Step
1. Disconnect the
connecting wires.
1
Remove the 2 screws
and disconnect the
power supply wire.
2
Remove the screws
and disconnect the
connecting wires of
rooms A ~ E.
3
Remove the screw to
detach the earth/ground
wire.
4
Remove the 8 screws
on the wire fixtures.
5
Remove the insulation
sheets.
6
Remove the 2 screws,
and then the partition
plate (2).
6
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Connecting wire
(R20769)
Power supply wire
Earth/ground wire
Insulation sheet
Wire fixture
Insulation sheet
Wire fixture
(R22549)
Partition plate (2)
(R18090)
Si121293EC
Points
4-room models have no
connector for room E.