Si121293EC
Step
3. Remove the control PCB.
1
Disconnect the
connectors [HL402] and
[HN402] from the
inverter PCB.
2
Disconnect the
connectors [DCP2] and
[DCM2].
3
Disconnect the
connectors [S401] and
[S411].
4
Disconnect the
connectors [S206],
[S209] and [S210] from
the control PCB.
5
Remove the screw of
the earth/ground wire
under the electrical box.
Removal Procedure
Procedure
[S411]
[S401]
[HN402]
Inverter PCB
[S209]
[S210]
Earth/ground wire
[HL402]: blue
[HN402]: white
[DCP2]: purple
[DCM2]: brown
[S401]:
[DCP2]
for [S202] on control PCB
[S411]:
for [S211] on control PCB
[DCM2]
[HL402]
(R18098)
[S206]:
[S206]
for [S503] on service PCB
[S209]:
for [S501] on service PCB
[S210]:
for [S502] on service PCB
(R17984)
(R20770)
PCBs
Points
13