Continental Girbau L28STK30G Owner's Manual page 29

30 lb. stack laundry dryer gas
Table of Contents

Advertisement

TROUBLE
Dryer too hot.
Troubleshooting Chart
Troubleshooting Chart
CAUSE
Incorrect main burner orifices.
Inadequate make-up air.
Lint accumulated.
Exhaust duct dampers.
High gas pressure.
Partially restricted or
inadequately sized exhaust system.
Defective thermostat.
Replace orifices. Check factory for correct size.
Make-up air must be 4 to 6 times the exhaust area of
the dryer.
Remove lint.
Must be full open- replace if not.
Adjust gas pressure per rating plate.
Check service section for recommended sizes.
Remove obstructions or lint build up from duct
work. NEVER use smaller size exhaust duct.
ALWAYS use larger size.
Replace thermostat.
Page 29
REMEDY

Advertisement

Table of Contents