Caution - in case of grounding
Pos. Description

8.17. Grounding

» Never obstruct exits and escape routes!
» Check for leaks on the entire hull, first at bilge level, the keel and the rudder shafts and in
» Return to port immediately and drive at reduced speed, reduce sail area, avoid vivid dynamic
movements and accelerations
8.18. List of through Hull Fittings (locations see drawing)
» Check the appendages and openings and structure again when returning to port
» Have the boat inspected on the dry thoroughly
1
Intake fushing water toilet
2
Deck suction black water
3
Discharge black water tank
4
5
6
Discharge sink
7
8
Discharge sump of galley sink
Discharge el. bilge pump
11
12
Intake generator cooling
particular at those places where hull fittings and openings have been fitted (Propulsion, sea
14
Discharge heater
cocks etc.).
17
Discharge manual bilge pump
18
19
Drain gas box
The following skin fittings are fitted in the hull of the craft. They provide the frontline defense against flooding and
should be regularly inspected for their condition. Valves should be frequently operated to ensure free movement.
It is recommended that all valves but drains & bilge discharges are closed when the craft is left unattended.
Vent black water tank
Vent fresh water tank
Discharge head/shower
10
Discharge A/C fwd cabin
Drain rudder upper bearing stb/port
Pos. Description
21
Drain anchor chain locker
22
23
24
25
Intake cooling engine saildrive
26
28
Discharge sump conpanionway
29
Discharge stb steering position
31
32
Exhaust engine
33
Exhaust generator
34
Filler fitting fresh water
Filler fitting diesel
Intake sea water A/C
Log/echosounder
Vent diesel tank
30
Discharge steering port, transom
Disharge sump A/C aft
70