Electrical Data; Performance Data; Scope Of Delivery - Omega OS 531 Installation And Operating Manual

Ultrasonic leak detector
Table of Contents

Advertisement

Measuring medium
Plug
Operating temperature
Battery life
Charging temperature
Charging time
Materials of the detector
Dimensions
Interface
Display
Laser pointer
WLAN
Camera
Headset
Weight

4.2 Electrical data

Power supply

4.3 Performance data

The table shows the detection distance of various hole diameters at different pressures in the lab environment and
with the trumpet on.
Pressure / diameter
0.5 bar
5.0 bar
5

Scope of delivery

The OS 531 layout in the transportation case is shown as below.
Compressed Air, refrigerants and any compressed gases
3.5 mm stereo phone jack for headset
0 ... +40°C
About 8 hours with wireless off
+10 ... +45°C
Around 3 hours
PC + ABS
See section 7.3.
Wireless connection to headset
USB port for charging and data exchange
3.5" color LCD
Wave length: 640 ... 660 nm
Output power: < 1.0 mW
2.4 GHz band
5.0 megapixels
Noise isolated and wireless
3.65 kg (full set)
Internal lithium-ion battery
0.1 mm
0.5 m
3.6 m
0.2 mm
1.7 m
11.5 m
0.5 mm
7 m
18 m