MOLEAER LOTUS Owner's Manual
Hide thumbs Also See for LOTUS:

Advertisement

Quick Links

MOLEAER LOTUS
NANOBUBBLE GENERATOR
Owner's Manual
IMPORTANT: READ, FOLLOW AND
SAVE THESE INSTRUCTIONS
CUSTOMER SERVICE / TECHNICAL SUPPORT
If you have questions or need to order
replacement parts, please contact:
CUSTOMER SERVICE:
Monday to Friday: 8:00 a.m. to 5:00 p.m. PST
Phone: +1 (424) 558-3567
Email: info@moleaer.com
WEBSITE:
www.moleaer.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LOTUS and is the answer not in the manual?

Questions and answers

Summary of Contents for MOLEAER LOTUS

  • Page 1 If you have questions or need to order replacement parts, please contact: CUSTOMER SERVICE: Monday to Friday: 8:00 a.m. to 5:00 p.m. PST Phone: +1 (424) 558-3567 Email: info@moleaer.com WEBSITE: www.moleaer.com MOLEAER LOTUS NANOBUBBLE GENERATOR Owner’s Manual IMPORTANT: READ, FOLLOW AND SAVE THESE INSTRUCTIONS...
  • Page 2: Table Of Contents

    MOLEAER LOTUS NANOBUBBLE GENERATOR Owner’s Manual Table of Contents Safety ...................................... 2 General Warnings ................................2 General Information ................................3 Key System Components ..............................3 Quick Startup Guide ................................4 Suction and Discharge Verification ............................. 4 Typical Operating Parameter Ranges ..........................5 Specifications ..................................
  • Page 3: Safety

    This Lotus nanobubble generator is for INDOOR USE WITH OXYGEN ONLY. RISK OF ELECTRICAL SHOCK. INSTALLERS, OPERATORS, AND OWNERS MUST READ...
  • Page 4: General Information

    Figure 2. Lotus Pump & Piping Read instructions thoroughly prior to installation and use. All Lotus products are factory adjusted for optimal nanobubble production. Note that the actual unit sold may differ slightly from the description in the manual without any difference in the functionality and performance of the unit.
  • Page 5: Quick Startup Guide

    0. as possible and discharges below the surface of the water. 5. Open the enclosure of the Lotus by lifting the lid of Figure 5. Lotus Tank Installation by Water Level the box. Open any isolation valves between the unit and tank on both the inlet and discharge pipes.
  • Page 6: Typical Operating Parameter Ranges

    Refer to the Appendix for additional detail regarding the recommended operating envelope for this unit. Gas Connection Moleaer Lotus generators come with a ¼” barb fitting. The unit is designed to be used with industrial-grade oxygen. www.moleaer.com...
  • Page 7: Included Accessories

    Lotus installation location. Refer to the Location Requirements section of this guide for additional details. Upon delivery, unbox and inspect the Lotus for any damage Gas Tube or loose parts that may have occurred during transport.
  • Page 8: Pipe Assembly

    Refer to the pipe connections extending from the base of Parts, Tools, and Materials the Lotus that are shown in Figure 11. Using PVC primer and cement, glue elbows to the first straight, horizontal pipe The following is a list of various parts, material and tools segments of the suction and discharge piping, and then required for installation and startup of the equipment.
  • Page 9: Connecting The Oxygen

    Lotus. Connect the hose between the supplied regulator install a check valve on the end of the intake. and the hose barb on the right side of the Lotus. Install hose clamps. Open...
  • Page 10: Startup

    Once the Lotus nanobubble system is operating normally, and the water in the tank is freshly filled, test the DO level continuously while letting the Lotus run, and when the desired DO level is reached make a note of the run time and set up the timer to run for that period (no less than one hour).
  • Page 11: Regulator/Flow Control

    Do not use thread tape or paste on the tank or the regulator connections. Connect the supplied hose between the Regulator and the Lotus, clamping the hoses with the supplied hose clamps. Setting the flow rate will be based on environmental factors, such as temperature, volume of water in tank, total water used daily, level of fertilizers and types of fertilizer.
  • Page 12: Pump Maintenance

    MOLEAER LOTUS NANOBUBBLE GENERATOR Owner’s Manual Pump Maintenance 6. Put the basket back into the housing. Be sure to align the notch in the bottom of the basket with the rib in the bottom of the housing. Do NOT open the strainer basket if pump fails to 7.
  • Page 13 Be sure to re-open valves prior to operating. Always disconnect power to the Lotus generator and / or pump at the circuit breaker before servicing the Priming the Pump pump.
  • Page 14 MOLEAER LOTUS NANOBUBBLE GENERATOR Owner’s Manual 1. Loosen the pump lid. Do NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged, and the pump will 2. Allow pump strainer basket to fill with water.
  • Page 15: Drawings

    MOLEAER LOTUS NANOBUBBLE GENERATOR Owner’s Manual Drawings Figure 11: Lotus Isometric Installation Diagram Figure 12: Lotus Installation Diagram from Top www.moleaer.com...
  • Page 16 MOLEAER LOTUS NANOBUBBLE GENERATOR Owner’s Manual Figure 13: Lotus Enclosure Dimensions www.moleaer.com...
  • Page 17: Solvent Welding Pvc Pipe

    MOLEAER LOTUS NANOBUBBLE GENERATOR Owner’s Manual Solvent Welding PVC Pipe Figure 14. How to Glue Piping Once the primer has been applied to both surfaces, • the cement must be applied within 5 minutes. If not, you MUST prime the surfaces again before applying cement.
  • Page 18: Cleaning And Sanitizing

    The system is unable to reach 80% of specified 1. Turn off the pump and drain any water in the nominal gas flow with gas flow valve wide open. system. Isolate the Lotus from the tank. • The normal increase in dissolved oxygen in one 2.
  • Page 19 MOLEAER LOTUS NANOBUBBLE GENERATOR Owner’s Manual Figure 15. CIP Tubing Figure 11. Location of Clamp and Check Valve Figure 12. Clamp Disconnected and CIP Tube Inserted into Nanobubble Generator www.moleaer.com...
  • Page 20: Operation Checklist

    MOLEAER LOTUS NANOBUBBLE GENERATOR Owner’s Manual Operation Checklist Model Component Instructions Power light Check the light. Green: Running; Red: Powered but not running, No light: No power Gas Leakage Use soapy water to check the gas leakage on the joints and fittings.
  • Page 21: Preventive Maintenance Checklist - Recommended Monthly

    MOLEAER LOTUS NANOBUBBLE GENERATOR Owner’s Manual Preventive Maintenance Checklist - Recommended Monthly Part Number Description 99V0-079 Solenoid valve 45P0-001 Pump 99J0-140 Gas Assembly 99B0-036 Tubing 45J0-003 Pressure Gauges Gas Operating Pressure Water Operating Pressure www.moleaer.com...
  • Page 22: Troubleshooting Guide

    MOLEAER LOTUS NANOBUBBLE GENERATOR Owner’s Manual Troubleshooting Guide Problem Possible Cause Corrective Action Pump Will Not • Air being drawn into pump • Check suction piping and valves on suction line. Prime suction. • Secure lid on pump strainer basket and be sure lid •...
  • Page 23: Limited Warranty

    Limited Warranty Moleaer warrants that the Goods will be free from defects in material and workmanship for a period of twelve (12) months from the date of first purchase (provided, however, that if Buyer is not able to provide proof of the date of purchase, the warranty period will run for eighteen (18) months from the date of manufacture) (the “Warranty Period”).
  • Page 24 MOLEAER LOTUS NANOBUBBLE GENERATOR Owner’s Manual 20800 BELSHAW AVENUE CARSON, CA 90746 USA +1-424-558-3567 info@moleaer.com www.moleaer.com Revision 07052022 www.moleaer.com...