Download Print this page

Haier CANDY CSS4 1272D3/1-S Technical Notes page 4

Advertisement

4)
Error code Table Detected for RAPIDO' models range
ERROR CODE
E01
E02
E03
E04
E05
E06
E07
E08
E09
E11
E12
E13
D.R.
Any change or alteration whatsoever of this document is formally prohibited except with the previous consent of the issuer.
Cuore Three phase Power Card – GEN3
MOST PROBABLE REASON FOR THE ERROR CODE & SUGGESTED CHECK
Door Safety Lock Device and/or Wiring and connections. Mechanical issue
between door hook and door lock device .
Cause 1: the water load phase was not completed in the expected time.
Defective solenoid valve, Charging Tube Water choking,
triac
and/or Wiring,
--------------------------------------------------------------
Cause 2: the water load phase was not completed in the correct way (Check
both wiring and electrical connections on the drain pump or check drain pump
con winding interrupted) (Also see E03)
The Water Drain Phase was not completed within the designed limit time.
Clogged Filter, Drain Pump, Drain Hose, Drain outlet.
Several interventions by the Anti-flood Safety Contact of APS Pressostat (10).
Solenoid Valve stuck open, defective APS Pressostat and/or Wiring.
NTC Temperature Reading Probe open or short circuit and/or Wiring.
OUT OF BALANCE INTERVENTION COUNTER (run spin-dryer failure). Customer
has washed with an unbalanced load. ( Provide explanations and suggestions
about the loading mode ) (only in the Eeprom)
Check the door lock and door lock wiring & connections. (locked in closed
position). Make sure the motor does not have an earth leak. Only for WM with
three-phase motor, make sure that the inductor does not have an earth leak.
Electric Module. (Very rare)
Check whether the motor connector is bent or not properly connected.
Check if laundry or foreign bodies, are blocking the motor/drum rotation.
Defective Tachometric Dynamo (opened or shorted) and/or Wiring.
Resistance value of Tachometric coil for CESET Triphase Motor:
Resistance value of Tachometric coil for WELLING Triphase Motor:
Defective "Cuore" Electric Module (IGBT check damaged Motor) and/or Wiring.
Dryer NTC defective and / or wiring.
Ambient temperature close to 0 ° C.
Important: must also check the status of manual reset safety thermostats
(Reset them if they have worked to ensure that the user has not interrupted a
drying cycle).
Issue with the drying system: Drying heater defective (Check for correct
readings via the test routine procedure). Wiring/connection to dryer heater
defective, check NTC drying probe, possible effect as a result of E11 error
detection, Safety thermostat intervention TOC.
Missing communication between "Cuore" Electric Module and Display Electric
Module and/or Wiring.
©
2019 – HAIER EUROPE SERVICE ITALIA
possible burning of command on the Electric Module.
Network
Low pressure
116 Ω
(20°C)
67 Ω
(20°C)
4

Advertisement

loading