Command And Response Table For Sis Commands - Extron electronics RGB 203 Rxi User Manual

Three input, universal computer-video interface
Hide thumbs Also See for RGB 203 Rxi:
Table of Contents

Advertisement

Command and Response Table for SIS Commands

Command
Input selection
Select input
Example:
Horizontal shift
Set horizontal shift
Example:
Increment horizontal shift
value
Decrement horizontal shift
value
Vertical shift
Set vertical shift
Example:
Increment vertical shift value
Decrement vertical shift
value
View information, part number, and firmware requests
Information request
Example:
Request for a part number
Query firmware version
ASCII
Response
Command
(unit to host)
(host to
unit)
X!]
X!
!
Chn
]
3!
Chn
3
X@
X@]
Hph
H
]
Hph+028
28H
X@]
+H
Hph
X@]
-H
Hph
X@
X@]
/
Vph
]
-5/
Vph-005
X@]
+/
Vph
X@]
-/
Vph
X! •
I
Chn
Hph
X$ •
Hrt
Vrt
Chn3
Hph+028
Hrt48.400
X^]
N
X#]
Q
Additional Description
Select input X! . X! = 1, 2, or 3.
Select input 3.
Set horizontal shift value to X@ . Shift
control ranges from -127 to +127.
Set horizontal shift value to +28.
Increases horizontal shift value by 1.
Decreases horizontal shift value by 1.
Set vertical shift value to X@ .
Set vertical shift value to -5.
Increases vertical shift value by 1.
Decreases vertical shift value by 1.
X@ •
X@ •
View the input selection X! , horizontal
Vph
X$]
and vertical shift values X@ , and
horizontal and vertical frequencies X$ .
Vph-005
Input 3, horizontal shift +28, vertical
Vrt60.000
shift -5, horizontal frequency 48.4 kHz,
vertical frequency 60 Hz.
View the part number X^ .
X^ =
60-509-01
ADSP
60-509-02
View the currently installed version of
the firmware X# .
RGB 203 Rxi • SIS Commands
for RGB 203 Rxi with
for RGB 203 Rxi with EDID
26

Advertisement

Table of Contents
loading