Setting Of Dip-Switch (At Delivery); Attention For Test Run - Mitsubishi Electric CITY MULTI PEFY Series Technical & Service Manual

Air-conditioners for building application, ceiling concealed, indoor unit
Hide thumbs Also See for CITY MULTI PEFY Series:
Table of Contents

Advertisement

TROUBLESHOOTING-Setting of Dip-switch (at delivery)

7-3. Setting of Dip-switch (at delivery)

Models
SW1
PEFY-P15
ON
NMHU-E2
1
2
3
4
5
6
SW1
PEFY-P18
ON
NMHU-E2
1
2
3
4
5
6
SW1
PEFY-P24
ON
NMHU-E2
1
2
3
4
5
6
SW1
PEFY-P27
ON
NMHU-E2
2
3
4
5
6
1
SW1
PEFY-P30
ON
NMHU-E2
1
2
3
4
5
6
SW1
ON
PEFY-P36
NMHU-E2
1
2
3
4
5
6
SW1
ON
PEFY-P48
NMHU-E2
1
2
3
4
5
6
SW1
ON
PEFY-P54
NMHU-E2
1
2
3
4
5
6
ON
1
2
3
4
5
6
7
8
9 10
1
1
The figure at left shows that the switch is set to 1.
2
2
3

7-4. Attention for test run

 Check that the drain-up mechanism is working properly, that no water is leaking from pipe connections, and that the fan is
operating.
• For new installation, check the above items before completing ceiling work.
(1) Remove the cover from the water supply inlet on the indoor unit pipe.
(2) Insert the end of the pump or the tank into the drain pump. (Water may leak if it is not inserted properly.) Then, fill the
water supply pump from a water supply tank.
(3) Perform a test run in the Cooling mode, or connect the connector to the ON-side of the SWE on the indoor unit control
board.
(The drain pump and the fan will be forced into operation without being started from the remote controller.)
SWE
Connector
OFF
ON
<OFF>
(4) Check for normal operation, stop the test run, and shut off the main power. Disconnect the connector that is connected
to the ON-side of SWE, if applicable. Connect it to the OFF-side, and then replace the cover to the water supply inlet
as it was.
SWE
Connector
ON
OFF
<ON>
HWE1212A
S W2
ON
ON
7
8
9 10
1
2
3
4
5
6
1
2
S W2
ON
ON
7
8
9 10
1
2
3
4
5
6
1
2
S W2
ON
ON
7
8
9 10
1
2
3
4
5
6
1
2
S W2
ON
ON
7
8
9 10
2
3
4
5
6
2
1
1
S W2
ON
ON
7
8
9 10
1
2
3
4
5
6
1
2
S W2
ON
ON
7
8
9 10
1
2
3
4
5
6
1
2
S W2
ON
ON
7
8
9 10
1
2
3
4
5
6
1
2
S W2
ON
ON
7
8
9 10
1
2
3
4
5
6
1
2
The figure at left shows that the switches 1 through 5 are set to ON and 6 through 10 are set to OFF.
SWE
OFF
ON
<ON>
SWE
OFF
ON
<OFF>
Dip-SW
SW3
S W4
ON
3
4
5
6
7
8
9 10
1
2
3
4
5
SW3
S W4
ON
3
4
5
6
7
8
9 10
1
2
3
4
5
SW3
S W4
ON
3
4
5
6
7
8
9 10
1
2
3
4
5
SW3
S W4
ON
3
4
5
6
7
8
9 10
2
3
4
5
1
SW3
S W4
ON
3
4
5
6
7
8
9 10
1
2
3
4
5
SW3
S W4
ON
3
4
5
6
7
8
9 10
1
2
3
4
5
SW3
S W4
ON
3
4
5
6
7
8
9 10
1
2
3
4
5
SW3
S W4
ON
3
4
5
6
7
8
9 10
1
2
3
4
5
15
SW5
S W7
ON
220V
240V
1
2
3
SW5
S W7
ON
220V
240V
1
2
3
SW5
S W7
ON
220V
240V
1
2
3
SW5
S W7
ON
220V
SWC
240V
Standard
SWA
2
3
1
1
Indicate
SW5
S W7
ON
"標準"
220V
240V
1
2
3
SW5
S W7
ON
220V
240V
1
2
3
SW5
S W7
ON
220V
240V
1
2
3
SW5
S W7
ON
220V
240V
1
2
3