Electrical disconnect
(purchased separately)
Indoor unit power wires
Outdoor unit power wires
Outdoor unit
Indoor & Outdoor
connective wires
(purchased separately)
NOTICE
The diagrams are for explanation purpose only. Your machine may be slightly different.
The actual shape shall prevail.
Outdoor Unit Wiring
WARNING
Before performing any electrical or wiring
work, turn off the main power to the system.
1. Prepare the cable for connection.
a. You must first choose the right cable
size.
NOTICE
In North America, choose the cable type
according to the local electrical codes
and regulations. In North America, please
choose the right cable size according to
the Minimum Circuit Ampacity indicated
on the nameplate of the unit.
b. Using wire strippers, strip the jacket
from both ends of the cable to reveal
approximately 15cm (6") of wire.
c. Strip the insulation from the ends.
d. Stranded wire requires u-lugs or ring
terminals to be crimped onto the ends
of the wire.
 Page 34 
Electrical disconnect
(purchased separately)
Indoor unit
NOTICE
When connecting the wires, strictly
follow the wiring diagram found
inside the electrical box cover.
2. Remove the electric cover of the
Electrical disconnect
(purchased separately)
Electrical heater unit power wires
Electrical
heater
unit
outdoor unit. If there is no cover
on the outdoor unit, take off the
bolts from the maintenance board
and remove the protection board.
Cover
Screw

Advertisement