  • Page 1 11D Series-Fixed Speed/Inverter Split Type Room Air Conditioner For trouble free services please register with our Customer Care on 180030000011 or write to us at : mideacare@carriermidea.com...
  • Page 3 SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury.
  • Page 4: Safety Precautions

    SAFETY PRECAUTIONS CAUTION Ventilate the room well When the air filter is to be Do not put objects like thin when used together removed, do not touch the rods into the panel of blower with a stove, etc. metal parts of the unit. and suction side.
  • Page 5: Operating Instructions

    (C) Display for D-6 Models Model Name And Dimensions MODEL WIDTH (mm) HEIGHT (mm) DEPTH (mm) 9000 Btu 12000 Btu 18000 Btu 24000 Btu 1030...
  • Page 6: Special Functions

    OPERATING INSTRUCTIONS Special functions Refrigerant Leakage Detection With this new technology, the dipsplay area will appear EC (if applicable) and the LED indication lamps continue flashing when the outdoor unit detects refrigerant leakage. (Optional): Louver Angle Memory Function Within the scope of safety angle, it will memorize the open angle of horizontal louver. If it exceeds, it will memorize the boundry of safety angle.
  • Page 7 OPERATING INSTRUCTIONS NOTE: This manual does not include Remote Controller Operations, see the <<Remote Controller Instruction>> packed with the unit for details. Operating temperature Mode Heating operation Cooling operation Drying operation Temperature Room temperature Outdoor temperature ( For the models with low temperature cooling system (For special tropical models) (For special tropical models)
  • Page 8 OPERATING INSTRUCTIONS Airflow direction control Adjust the air flow direction properly otherwise it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually. To set the vertical air flow(Up--Down) direction Range Perform this function while the unit is in operation.
  • Page 9 OPERATING INSTRUCTIONS How the air conditioner works AUTO operation When you set the air conditioner in AUTO mode, it will SLEEP operation automatically select cooling, heating(cooling/heating 7 hours timer off models only), or fan only operation depending on set temperature and the room temperature. The air conditioner will control room temperature Temperature automatically to the temperature point you set.
  • Page 10 CARE AND MAINTENANCE Care and Maintenance Cleaning the Grille, Case and Remote Controller Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. NOTE: Power supply must be disconnectd before cleaning the indoor unit.
  • Page 11 CARE AND MAINTENANCE 4. Remove the Air Freshening Filter from its supporting frame (on some models). Clean the air freshening filter at least once a month, and replace it every 4-5 months. Clean it with vacuum cleaner, then dry it in cool place.
  • Page 12 OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection The compressor can't restart for 3-4 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached.
  • Page 13: Operation Tips

    OPERATION TIPS 8. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed. 9.
  • Page 14 TROUBLESHOOTING TIPS Troubleshooting Tips If one of the following faults occurs, stop the air conditioner immediately, disconnect the power and then connect it in again. If the problem still exists, disconnect the power and contact the nearest customer service center. OPERATION indicator or other indicators continue flashing.
  • Page 15 Please be aware that you are a responsible consumer under the e-waste rules. Kindly take note of the symbol below which connotes that you should not dump any of the electrical and electronic equipments including Midea air-conditioners in garbage bins, neither should you dispose off the same through any scrap dealers.
  • Page 16 180030000011 or visit our website for collection center. DO'S & DONT'S DO'S Contact only a Midea authorised dealer for the purpose of installation or de-installation of your air-conditioner Contact the Service Centre or an Authorised Dealer in case of any...
  • Page 17 DON'T'S Do not dump the air conditioner in garbage bins Do not dispose off your air conditioner to any scrap dealer Do not repair your air conditioner on your own Do not dismantle your air conditioner on your own Do not store the air conditioner in your house after it becomes non- operational or after it suffers any accidental breakage or damage...
  • Page 18 CARRIER MIDEA INDIA PRIVATE LTD. (hereinafter referred to as "The Company), hereby warrants to the original domestic purchaser (here in after called the "said purchaser") of the airconditioning unit (as detailed within the Warranty Registration Card and here in after referred to as the "said unit") that the said...
  • Page 19 Condenser and Evaporator is found defective if the air conditioner is installed near the muddy sewages because toxic gases harmful for the AC vii. Damage to the product due to operation in an abnormally corrosive alkaline / acidic atmosphere.
  • Page 20 Midea copy Carrier Midea India Private Ltd. Customer copy Carrier Midea India Private Ltd.
  • Page 21 consequential) of whatsoever arising out of the use or inability to use the product. consequential) of whatsoever arising out of the use or inability to use the product.
  • Page 22 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.