Advertisement

Quick Links

gesis® SPZ
Distribution box – for special applications
User manual
Doc. No. BA001298
Last Update: 09/2022 (Rev. A)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the gesis SPZ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wieland gesis SPZ

  • Page 1 gesis® SPZ Distribution box – for special applications User manual Doc. No. BA001298 Last Update: 09/2022 (Rev. A)
  • Page 2 Copyright Act. Alteration or abridgement of this document without the express written consent of Wieland Electric GmbH is prohibited. gesis® is a trademark of Wieland Electric GmbH. Other names may in this assembly manual men- tioned product and brand trademarks or registered trademarks of their respective owners could be used, whose use by third parties for their own purposes could violate the rights of the owners.
  • Page 3: Table Of Contents

    Pluggable connections with ready-made connectors 8.3.3 Connectors with non-pluggable input 8.3.4 Fitting the flat cable adapter to the flat cable 8.3.5 Data line 8.3.6 Connecting the earthing point Commissioning Operation Maintenance Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 4 Table of Contents Disassembly 12.1 Disassembly steps 12.2 Storage 12.3 Recommissioning Accessories Disposal Service and Support Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 5: About This Manual

    This user manual provides technical staff with information about the configuration, operation and functionality of the gesis® SPZ distribution box. You can find further information on our website www.wieland-electric.de or via the QR code. NOTE Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 6: Symbols And Notations

    Notes concerning the special functions of the device. NOTE Instructions also tell you about a potentially harmful situation. If it is not avoided, the system can be damaged or something in their environment. Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 7: Safety

    You can find the relevant CE declaration at: https://eshop.wieland-electric.com or via the QR code below. Navigate to the download area of your product. You will then find the CE declaration under the item "EC Declaration of Conformity". Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 8: General Product Information

    The product is a pre-wired distribution box for pluggable electrical installation. The distributors are manufactured according to IEC 61439. The Wieland gesis® SPZ distribution boxes are designed for various applications and provide a quick, easy and simple system solution. Thanks to the gesis® and RST®...
  • Page 9: Product Designs

    For details of the technical data, refer to chapter 6 "Technical Data", p. 11. Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 10: Areas Of Application

    RST® installation connector systems. Figure 2: gesis® SPZ as a checkout counter distributor Figure 3: Distribution fuse board for decentralized electrical installation for EV charging applications Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 11: Technical Data

    QR code below. Navigate to the "Technical Data" area of your product. You will find the necessary data here. You can also generate and download a product data sheet as a PDF file in the "Data Sheet" area. Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 12: Dimensions

    QR code below. Navigate to the "Technical Data" area of your product. You will find the desired data under "Dimensions". The dimensional drawings are available in the Downloads area. Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 13: Mounting

    MICRO Create load relief Release interlock To disconnect the connector, it is not necessary to open the distribution box. The internal wiring on NOTE the connector is done at the factory. Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 14: Pluggable Connections With Ready-Made Connectors

    Connecting the earthing point In order to ground the gesis® SPZ distribution box, connect the protective conductor connections to the ground connections on the housing and, if applicable, the cover in accordance with standards. Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 15: Commissioning

    During installation and commissioning, you must make sure that the necessary EMC directives are complied with. For further details on the mechanical or electrical data, see the enclosed documentation in the scope of delivery or at https://eshop.wieland-electric.com. Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 16: Operation

    Normally, there is no need to operate the system distributor. If protection/switching devices have tripped or other defects are identified, the relevant qualified electrician must be informed. Do not switch on the devices independently. Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 17: Maintenance

    • Changes to the system distributor render this manual invalid. The qualified electrician who made the change is responsible for updating or creating a new manual. Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 18: Disassembly

    Store the system distributor in a dry place protected from mechanical damage until it is commis- sioned or recommissioned. 12.3 Recommissioning For information on correct recommissioning, please refer to chapter 9 "Commissioning", p. 15. Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 19: Accessories

    Accessories ACCESSORIES For compatible accessories, visit https://eshop.wieland-electric.com or scan the following QR code. Navigate to your product. The "Accessories" area contains a list of compatible accessories. Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 20: Disposal

    EAK: 16 02 16 If the system distributor is defective, it must be disposed of or sent to Wieland Electric GmbH for re- pair. To initiate the process, contact your responsible contact partner.
  • Page 21: Service And Support

    Tel. +49 951 9324-0 +49 951 9324-198 E-mail info@wieland-electric.com http://eshop.wieland-electric.com http://www.wieland-electric.com UKCA – for UK: Wieland Electric Ltd | Ash House, Tanshire Park | Shackleford Road | Elstead, Godalming GU8 6LB Wieland Electric GmbH | BA001298 | 09/2022 (Rev. A)
  • Page 22 Wieland Electric GmbH Brennerstraße 10 – 14 DE-96052 Bamberg Tel +49 951 9324-0 Fax +49 951 9324-198 info@wieland-electric.com www.wieland-electric.com...