Download Print this page

Electrical Components - Daikin R15LV14 Removal Procedure

Advertisement

Si011282EB

3. Electrical Components

Warning
Step
Pull out the 5 terminals
1
from the capacitor.
Loosen the 2 screws of
2
the capacitor fixing
band and remove the
capacitor.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
to relay connector
for fan motor (1):
black
to relay
connector for
fan motor (3):
white
Capacitor
(R18568)
to terminal board
(2): black
to compressor
(R): red
to compressor
(S): yellow
(R19170)
Capacitor
fixing band
(R18569)
Electrical Components
Points
5