INSTALLATION MANUAL Split System air conditioners Installation manual English Split System air conditioners R71B7V1 RY71B7V1 R71B7W1 RY71B7W1 R100B7V1 RY100B7V1 R100B7W1 RY100B7W1 R125B7W1 RY125B7W1 RP71B7V1 RYP71B7V1 RP71B7W1 RYP71B7W1 RP71B7T1 RP100B7V1 RYP100B7V1 RP100B7W1 RYP100B7W1 RP100B7T1 RP125B7W1 RYP125B7W1 RP125B7T1...
Page 2
™ËÌ›ˆÛË Nota tal como estabelecido no Ficheiro Técnico de Construção DAIKIN.TCF.004 / DAIKIN.TCF.016 e com o parecer positivo de KEMA de acordo com o Certificado 81728-KRQ/ECM98-4341 / 59277-KRQ/ECM95-4233 . Bemærk som anført i den Tekniske Konstruktionsfil DAIKIN.TCF.004 / DAIKIN.TCF.016 og positivt vurderet af KEMA i henhold til Certifikat 81728-KRQ/ECM98-4341 / 59277-KRQ/ECM95-4233 .
Page 3
B1 B2 C D1 D2 E L1/L2 ≥50(100) ≥100 ≥100 ≥100 ≥100 ≤500 ≥1000 ≥150 ≥150 ≥150 ≤500 ≥1000 ≥500 ≤500 ≥500 ≥1000 D 2 D 2 ≥50(100) ≥500 L1<L2 ≥50(100) ≥500 L2<L1 ≥750 0<L1≤ 1 / 2 H ≥150(250) ≤500 ≥1000 L1≤H...
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY Handling TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE As shown in the figure, bring the unit slowly by grabbing the left and EQUIPMENT AND HAVE THEM INSTALLED BY A right grips.
Precautions Remove the rear suction grille to prevent snow from accumulating on the rear fins. Do not install or operate the unit in rooms mentioned below. Where mineral oil like cutting oil is present. If you install the unit on a building frame, please install a waterproof plate (within 150 mm of the underside of the unit) in Where the air contains high levels of salt such as that near the order to avoid the drainwater dripping.
In case of installing multiple units (2 units or more) in lateral NSTALLATION SERVICING SPACE connection per row. The numerical figures used herein represent the dimensions for the models R(Y)(P)71 to 125. Figures in ( ) indicate the dimensions for the models R(Y)(P)100 and 125.
The minimal piping length should be 7.5 m. If installation is NOTE Refer to the table for stop valve tightening performed with less field piping, the system will be overcharged torques. (abnormal HP, etc.). If the distance between indoor and outdoor unit is less than 7.5 m, please make sure that the piping length is ≥...
Leak test In case of simultaneous operation system Evacuate the pipes and check vacuum. (No pressure increase Upward and downward piping should be performed at the main for 1 minute.) piping line. Break the vacuum with a minimum of 2 bar of nitrogen. Use branch piping kit (optional) for branching refrigerant pipes.
LECTRICAL WIRING WORK R22: All wiring must be performed by an authorized electrician. RY71~125 G = (L1-7.5 m) x 0.05 + L2 x A + L3 x A All components procured on the site and all electric construction R71~125 G = (L1-7.5 m) x 0.03 + L2 x A + L3 x A should comply with the applicable local and national codes.
EST OPERATION For the test run procedure, refer to the indoor unit installation manual. ISPOSAL REQUIREMENTS Dismantling of the unit, treatment of the refrigerant, oil and any other parts should be done in accordance with the relevant local and national regulations. IRING DIAGRAM : FIELD WIRING : BLACK...
Page 11
R407C R407C 1~50Hz 3N~50Hz 3~50Hz 230V 400V 230V L1 L2 L3 N L2 L3 l ll lll...