Split unit air conditioner
ceiling mounted c series; e series; fl-e series; fh-c series; fly-e series; fhy-c series
cooling only & heatpump [50hz] (78 pages)
Si011282EB Table of Contents 1. Outer Panels ...................2 2. Outdoor Fan / Fan Motor.................3 3. Electrical Components ................5 4. Capillary Tube ..................9 5. Compressor ASSY ................10 Note: The illustrations may be slightly different depending on the model. Removal Procedure...
Outer Panels Si011282EB 1. Outer Panels Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the 4 screws Some models have only 1 and remove the top screw on the left side of the Top panel panel.
Si011282EB Outdoor Fan / Fan Motor 2. Outdoor Fan / Fan Motor Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the nut and Nut size: M6 remove the outdoor fan.
Page 6
Outdoor Fan / Fan Motor Si011282EB Step Procedure Points Remove the 3 screws. Fan motor (R10461) Release the fan motor lead wire from the 2 hooks. (R15207) Remove the fan motor. (R15208) Removal Procedure...
Si011282EB Electrical Components 3. Electrical Components Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Pull out the 5 terminals Capacitor from the capacitor. (R18568) to relay connector for fan motor (1): to terminal board black...
Page 8
Electrical Components Si011282EB Step Procedure Points Remove the screw and remove the service cover sliding downward. Service cover (R18570) Remove the 3 screws on the terminal board and disconnect the connecting wire. Terminal board Connecting wire (R18571) Remove the screw and remove the wire fixture.
Page 9
Si011282EB Electrical Components Step Procedure Points Remove the screw and Some models have no earth detach the earth / / ground wire. ground wire. When reassembling, confirm the terminal location. Pattern 1 Earth / ground wire Earth / black ground brown wire (R21471)
Page 10
Electrical Components Si011282EB Step Procedure Points When replacing the Some models do not have a Fuse Fuse holder fuse, open the fuse fuse. holder. (R18576) Remove the 4 screws and remove the right side panel. Right side panel (R19563) Remove the 2 screws When reassembling, fit the and remove the lower hook of the bottom...
Si011282EB Capillary Tube 4. Capillary Tube Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas brazing machine.
Compressor ASSY Si011282EB 5. Compressor ASSY Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas brazing machine.
Page 13
Si011282EB Compressor ASSY Step Procedure Points Disconnect the Overload Black (C) compressor lead wires protector and remove the overload protector. Remove the gasket. Gasket Yellow (S) Red (R) (R21560) (R18582) Remove the 3 nuts of the compressor. (R18583) Removal Procedure...
Page 14
Compressor ASSY Si011282EB Step Procedure Points Heat up the 2 brazed Before heating up, make parts and disconnect sure to remove the sheets of them. putty so as not to burn them. (R18584) Lift up the compressor and remove it. (R18585) Removal Procedure...
Page 15
Revision History Month / Year Version Revised contents 06 / 2013 Si011282E First edition 12 / 2013 Si011282EA Model addition: RE15/20/25LV1, RE20/25MV1V 03 / 2015 Si011282EB Model addition: RNE25LV1, RNE15/20/25MV1, RNE15/20/25MV14, RNE20/25MV1V9...
Page 16
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.