Download Print this page

olympia electronics GR-796/ST/DUO/ADR Quick Start Manual page 2

Addressable self testing recessed non-maintained emergency ceiling mounted luminaire

Advertisement

Battery Connection
Connect the battery cable to its
Refit the luminaire to the bottom cover. Clean the
respective connector on the PCB.
luminaire's surface, install the included tie-wrap
to the included adhesive tether loop and fasten
securely the power cable in order to anchor it.
5
6
Bend one spring, to get into the holes of the suspended ceiling. Bend the other spring and push the
luminaire upwards until it is securely mounted. The device is now ready to operate.
7
NOTE!!
After finishing the installation you must power the luminaire for at least 24 hours in order to completely
charge the battery. The rated autonomy duration can be achieved after that time.
Battery Replacement
It can be done only by a competent person and after the mains interruption.
1. Disconnect mains, carefully remove the luminaire from the suspended ceiling, make sure that the springs do
not snap.
2. Remove the bottom cover (step 2 of installation procedure).
3. Disconnect the battery and install a new one of the same type and characteristics.
4.Refit the cover.
Important notice for the installed luminaires in one area !!!
The installer must connect the battery's connector first and then should power the luminaire.
The time between batteries connection must be, at least 1.5 minute.
With this variation, it is ensured that the non synchronized Automatic Autonomy Test for two or more luminaires
installed in one area, is not conducted in the same day.
Note: In case of mains power disconnection for a period of more than two months, the battery must be
disconnected.
Note: In case of battery replacement, this must be replaced with parts of the same type and characteristics. The
replacement must be performed by the manufacturer or a competent person.
Note: If the supply cable of the luminaire is damaged, it shall exclusively be replaced by a competent person in
order to avoid hazard.
ATTENTION
The light source of this luminaire is not user replaceable. When the light source reaches its end of life the
whole luminaire shall be replaced.
CAUTION : Do not view directly with bare eyes.
NOTE: LED= Light Emitting Diode
LABELING EXPLANATION:
X: Self contained
0: Non maintained operation (*)
A: Including test device
B: Including remote test mode
C: Including inhibiting mode
E: With non-replacable lamp(s) and/or battery
F: Automatic test gear complying with IEC 61347-2-7 denoted EL-T
60: 60 minutes duration, 180: 180 minutes duration, 480: 480 minutes duration
X
0
A B C E F
6 0
(*) Non Maintained operation: The luminaire lights its illumination source, only in power supply's failure.
4
Technical Characteristics
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
MAX. SUPPLY CURRENT
MINIMUM POWER FACTOR (λ)
U-OUT
Prated/Irated
INSULATION BETWEEN SUPPLY & CONTROL TERMINALS
INSULATION BETWEEN SUPPLY & BATTERY CIRCUIT
WORKING VOLTAGE AT WHICH THE INSULATION IS DESIGNED
WIRE CROSS SECTION
BATTERY (NiMH,
4HRMU15/15
)
CHARGE TIME
BATTERY PROTECTION
BATTERY SUPPLY CURRENT DURING EMERGENCY
BATTERY CHARGE CURRENT RANGE
BATTERY DISCHARGE CURRENT RANGE
MINIMUM DURATION
LIGHT SOURCE
EMERGENCY ILLUMINATION
INDICATIONS
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
CONTROL GEAR MAX. TEMPERATURE:tc
DEGREES OF COVER PROTECTION
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSION (L x W x H)
WEIGHT
GUARANTEE
CONTROL GEAR WITH AUTOMATIC TEST FUNCTION
Controlgear classification in accordance with IEC 62034: with automatic test function
The controlgear has mains-connected windings of transformer
The controlgear is proof against supply voltage polarity reversal
LED Characteristics
MANUFACTURER
MODEL NUMBER
VOLTAGE RANGE
NOMINAL POWER
CONNECTIONS
TEMPERATURE (tc)
LED Module Type
Warranty
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty is specified
in the official catalogue of Olympia Electronics and also in the technical leaflet, which accompanies each product. This
warranty ceases to exist if the buyer does not follow the technical instructions included in official documents given by
Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re-setting done by a third party,
unless Olympia Electronics has fully agreed to them in writing. Products that have been damaged can be returned to
the premises of our company for repair or replacement, as long as the warranty period is valid.
Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the buyer
depending on the reason of defection. Olympia Electronics reserves the right to charge or not the buyer the
transportation cost.
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
5
923796000_09_001
GR-796/ST/DUO/ADR
220-240V AC / 50-60Hz
3.3W / 3.8VA
17mA
0.87
5V
1.9W / 650mA
Basic Insulation
Basic Insulation
500V
2
2
2.5mm (stranded) 4mm (solid)
4.8V / 1.7Ah
24 hours
Deep discharge and overcharge protection
The control gear will recharge the battery normally after the test of 22.3
(Vbat=4.8V): 1h: 400-550mA, 3h: 290-405mA, 8h:125-170mA
110-135mA
130-550mA
1, 3, 8 hours manually selected (default 1h)
1 White Power LED
1h : 300lm
3h : 240lm
8h : 110lm
Charge - Fault (Lamp/Battery)
EN 60598-1, EN 60598-2-22, EN 55015 EN 61547, EN 61000-3-2, EN 61000-3-3
o
5 to 40
C
o
80 C at LD4
IP40
Up to 95%
ABS/PC
130 x 37mm
Ø
350gr.
3 years (1 year for the battery)
Olympia Electronics S.A.
1303225
2.7-2.95V
1.95W
Built-in main board
o
55 C max. across the board
BUILD IN
www.olympia-electronics.com
info@olympia-electronics.gr
923796000_09_001
European
manufacturers
GR-796/ST/DUO/ADR
ADDRESSABLE SELF TESTING RECESSED
NON-MAINTAINED EMERGENCY
CEILING MOUNTED LUMINAIRE
NM
ST
ADR
Light output
Battery
Non
SELF
300lm, 240lm
IP40
Ni-MH
Addres-
maintained
TESTING
110lm
sable
Thank you for your trust in our products
Olympia Electronics - European manufacturer
5 to
Duration
40 C
o
MAX. POWER
1h, 3h
CONSUMPTION
TEMPERATURE
8h
3.3W/3.8VA
RANGE

Advertisement

loading