Page 1
Model#PGD40iSCO 4000 Watt Inverter Generator OPERATOR’S MANUAL DO NOT RETURN TO STORE! Warning: The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. STOP HAVE QUESTIONS OR NEED SERVICE? 866-591-8921 support@pulsar-products.com...
CAUTION Pulsar Products reserves the right to make updates to this manual at any time. CAUTION indicates a potentially hazardous situation which, Please contact Pulsar Support at 866.591.8921 or if not avoided, may result in minor or moderate injury.
Safety Instructions Before operating your generator, you must read and understand the manual and familiarize yourself with the safe operation practices. NEVER use a generator indoors! Exhaust Avoid running the generator in the rain or and Carbon Monoxide can KILL YOU in very high, condensing humidity.
Names of Components Before operating your generator, you must read and understand the manual and familiarize yourself with the safe operation practices. Lifting Handle Fuel Tank Cap Left Enclosure Control Panel Recoil Start Spark Plug Access Rear Panel Right Enclosure Air Filter Access Oil Fill Access Muffler...
Control Panel CO SENTRY PROTE ION AGAIN RBON MONOXIDE SELECTOR SWITCH TO AVOID DAMAGE, DO NOT CONNECT OR DISCONNECT PARALLEL CABLES WHILE THE UNIT IS RUNNING.
Control Functions Overload Indicator (Red) Selector Switch INDICATOR LIGHT OFF - Ignition circuit is off, the fuel valve is closed, the engine will not run. RUN – Ignition circuit is on, the fuel valve is open, the choke is open, and the engine runs normally. When the overload indicator illuminates, the generator has START (CHOKE) –...
Control Functions Preparing Your Generator Fuel 2) "OFF" When the energy saving switch is set to the "OFF" position, the DANGER engine will run at rated speed, regardless of connected load. Fuel Tank Cap Gasoline is highly flammable and toxic. You must read and understand ALL safety instructions before fueling your generator.
Follow the checklist below before starting the generator. If any problems are found, do not use the generator until it has been repaired by an authorized Pulsar Products service center. Fuel Check fuel level; add if necessary. Check oil level; add if necessary.
Page 9
Using the Generator Range of Application Connecting Loads to the Generator ① Start the engine Before using the generator, please make sure that total load is ② Move Energy Saving switch to "OFF" within rated load range of the generator, otherwise the generator ③...
Fuel Tank and Fuel Clean √ Filter ** Fuel Hose Inspection Every Two Years Remove Displacement <225cc, every 125 hours; displacement Cylinder Head, Piston Carbon ≥225cc, every 250 hours. Deposit ** ** These tasks should be completed by an authorized Pulsar service center.
Page 11
This carburetor is not adjustable, only maintenance and cleaning as soon as possible per the table above. are possible. We strongly recommend leaving this work to an DANGER authorized Pulsar Service center. Oil Change Shut down the engine and allow it to cool before performing WARNING any service.
Service and Maintenance Fuel Filter Screen Spark Plug DANGER 1). Remove screws ③, to remove air filter housing ④; 2). Remove foam filter element ⑤; 3). Clean foam filter element with a mild soap solution, rinse NEVER approach the generator while smoking or with any ignition well and let it dry source! 4).
5). Using a Phillips screwdriver, open fuel drain valve on the 1) Worn out engine carburetor, and . drain remaining fuel into an approved 2) Cylinder head bolts have loosened, have an authorized Pulsar gasoline container. Service Center re-torque them properly 6).
Need help?
Do you have a question about the PGD40iSCO and is the answer not in the manual?
Questions and answers