Maintenance; Cleaning; Replacing The Protection Fuses (For Ac Models) - Datalogic DX8200 Installation Manual

Hide thumbs Also See for DX8200:
Table of Contents

Advertisement

MAINTENANCE

5 MAINTENANCE

5.1 CLEANING

Clean the laser beam output windows (Figure A, 3) periodically for correct operation of the
reader.
Dust, dirt, etc. on the window may alter the reading performance.
Repeat the operation frequently in particularly dirty environments.
Use soft material and alcohol to clean the windows and avoid any abrasive substances.
Clean the windows of the DX8200 when the scanner is turned off or at
least when the laser beam is not active.
WARNING

5.2 REPLACING THE PROTECTION FUSES (FOR AC MODELS)

The device must be opened by qualified personnel only.
WARNING
Before removing the fuses from DX8200, make sure the power supply
cable is disconnected to avoid shock or harm to the operator.
WARNING
Two protection fuses are located next to the on/off switch (Figure B ,3).
To replace them, turn the device off and disconnect the power supply cable; then, with a
screwdriver remove the fuses and replace them with new ones of the correct value (see the
following fuse selection table).
Connect the power supply cable and turn the device on again to verify the success of the
operation.
Version
110 - 230 Vac
Fuse
Type
3.15 A
F
5
51