In Current Limit- Active when any of the current limits are active. A current limit condition will
come from the current that is active at the time. There is a Factory Current Limit (set at the
factory) and a System Current Limit (set by the user on the System Setup page) the lower of the
two will normally determine the current limit. During a Home the Home Current Limit is active.
During the feed portion of a Move the Feed Current Limit is active. This is not a fault condition,
only an indication that the drive is limiting the current to the motor / actuator. This condition will
clear when the demand for the current is lowered.
2
Over Rated Current- Active when the continuous rated current (I
t) has been exceeded. By
default this causes a Fault Condition but may be selected to cause a warning or no fault
condition. If the Fault condition is removed it is the responsibility of the user to prevent the drive
from operating in this condition (see System Setup).
Stop- Indicates when the Stop is active.
Pause- Indicates when Pause is active
Jogging - Indicates when Jog + or Jog- is active
Jogging + -Indicates when Jog + is active
Default Mode Active- Indicates when the drive is in Default Mode. I the drive is enabled with
Default, Alternate or Host Mode will be active.
Alternate Mode Active- Indicates when Alternate Mode is active.
Host Mode Active- Indicates when Host Mode is active.
Homing- Indicates when a homing cycle is active.
Dedicated Move- Indicates when the Dedicated Move is active.
At Home Position- Indicates when the actual position is at the Home Position within the window
defined by the In Position Parameters (See In Position Window tab on the System Set-up Page)
At Dedicated Position- Indicates when the actual position is at the Dedicated Position within the
window defined by the In Position Parameters (See In Position Window tab on the System Set-
up Page)
Move Active- Indicates when any of the 4 Moves are active, will also remain active if the Move
Maintained Input function is active even the specified Move is complete.
Move 1-4 Active - Indicates when the specific Move 1-4 is active.
At Move 1-4 Position- Indicates when the specific Move is within the window defined by the In
Position Parameters (See In Position Window tab on the System Set-up Page). If the Move is
feed type move the output function will remain active during the feed portion of the move.
In Position- Indicates when the actual position is at the Commanded Position within the window
defined by the In Position Parameters (See In Position Window tab on the System Set-up Page)